Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp.
نویسندگان
چکیده
BACKGROUND Models of the dynamics of interstitial fluid-based continuous glucose sensors imply a variable sensor deviation from reference blood glucose (BG), depending on both sensor calibration procedure and BG dynamics. These effects could have a significant effect on the cross-interpretation of nonidentical accuracy studies. METHODS Hyperinsulinemic euglycemic and hypoglycemic clamps were performed on 39 subjects with type 1 diabetes wearing the Medtronic Continuous Glucose Monitoring System®. Sensor calibration and interstitial glucose (IG) dynamics were modeled and analyzed as potential confounders of sensor deviation from reference BG. RESULTS The mean absolute deviation (MAD) of sensor data was 20.9 mg/dl during euglycemia and 24.5 mg/dl during descent into and recovery from hypoglycemia. Computer-generated recalibration reduced MAD to 10.6 and 14.6 mg/dl, respectively. Modeling of IG dynamics reduced the MAD further to 10.0 and 10.4 mg/dl (using idiosyncratic parameters) or to 10.6 and 11.5 mg/dl (using model parameters common for all subjects), respectively. CONCLUSIONS The sensor MAD from reference is strongly influenced by the choice of calibration points. Thus, cross-experiment comparisons of sensor accuracy are likely to be heavily dependent on the employed calibration procedures. Demanding calibration points substantially differing in value was found to improve calibration effectiveness. Simulation using existing IG models and population parameters reduced the bias resulting from BG-IG dynamics.
منابع مشابه
Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring Devices
Evaluation of metabolic control of diabetic people has been classically performed measuring glucose concentrations in blood samples. Due to the potential improvement it offers in diabetes care, continuous glucose monitoring (CGM) in the subcutaneous tissue is gaining popularity among both patients and physicians. However, devices for CGM measure glucose concentration in compartments other than ...
متن کاملA multiple local models approach to accuracy improvement in continuous glucose monitoring.
BACKGROUND Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend on the implemented calibration algorithms, which do not compensate adequately for the differences of glucose dynamics between the compartments. Here we propose and validate an inno...
متن کاملPoint accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study
INTRODUCTION There is a need for continuous glucose monitoring in critically ill patients. The objective of this trial was to determine the point accuracy and reliability of a device designed for continuous monitoring of interstitial glucose levels in intensive care unit patients. METHODS We evaluated point accuracy by comparing device readings with glucose measurements in arterial blood by u...
متن کاملAccuracy of the Sof-sensor glucose sensor with the iPro calibration algorithm.
Corresponding Author: John B. Welsh, M.D., Ph.D., Medtronic, Inc., 18000 Devonshire St., Northridge, CA 91325; email address [email protected] Performance characteristics of devices that measure interstitial fluid glucose concentrations continue to improve. The overall accuracy of continuous glucose monitoring (CGM) systems depends on the sensor, the reference blood glucose concentrat...
متن کاملEvaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.
OBJECTIVE To compare the clinical accuracy of two different continuous glucose sensors (CGS) during euglycemia and hypoglycemia using continuous glucose-error grid analysis (CG-EGA). RESEARCH DESIGN AND METHODS FreeStyle Navigator (Abbott Laboratories, Alameda, CA) and MiniMed CGMS (Medtronic, Northridge, CA) CGSs were applied to the abdomens of 16 type 1 diabetic subjects (age 42 +/- 3 years...