Comparative Analysis of Hemagglutination Inhibition Titers Generated Using Temporally Matched Serum and Plasma Samples

نویسندگان

  • Gabriel N. Defang
  • Nicholas J. Martin
  • Timothy H. Burgess
  • Eugene V. Millar
  • LeNae A. Pecenka
  • Janine R. Danko
  • John C. Arnold
  • Tadeusz J. Kochel
  • Thomas C. Luke
چکیده

Influenza-specific hemaggluitination inhibition (HAI) antibody titer, an indicator of immunity to influenza, is often used to measure exposure to influenza in surveillance and immunogenicity studies. Traditionally, serum has been the specimen of choice for HAI assays, but a desire to reduce the amount of blood collected during studies and the availability of plasma in archived sample collections warrant the evaluation of plasma for HAI titer. Therefore, the relationship between serum and plasma HAI titer values is of great interest. Here, we compare HAI titers determined on temporally matched serum and plasma (citrated and heparinized) using influenza A and B viruses. Bland-Altman plots, McNemar's test, and geometric coefficient of variation were used respectively for evaluating agreement, correlation and variability in the serum-plasma titer results. We observed a high degree of agreement (80.5%-98.8%) and correlation (r = 0.796-0.964) in the serum and matched plasma titer values although plasma titers were generally lower than corresponding serum titers. Calculated seropositive (HAI ≥40) rates were higher using serum titers than with plasma titers, but seroconversion rates were unaffected by sample type. Stronger agreement and decreased variability in titers were seen between serum and citrated plasma than between serum and heparinized plasma. Overall, these data suggest that serum or plasma can be used in serodiagnostic HAI assays, but seropositive rates may be underestimated using plasma HAI titers. The type of anticoagulant present in plasma may affect HAI titer values and warrants further investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Titers of Hemagglutination Inhibition Antibodies against 2009 H1N1 Influenza Virus in Southern Iran

Background: Pandemic flu had at least two waves in Iran. Knowing how many of the general population were already exposed to this infection has a major impact on na-tional preventive measures. As of December 30, 2009, a total of 3672 confirmed cases of human infection with a novel Influenza A (2009 H1N1) virus had been reported in Iran with 140 deaths. Objective: In this study we aim to measure,...

متن کامل

Preparation of an Inactivated Egg Drop Syndrome Antigen for Using in Hemagglutination Inhibition Test.

To prepare hemagglutination inhibition (HI) antigen the egg drop syndrome virus (EDSV) was propagated in 10-day-old embryonated duck eggs. The virus antigen was inactivated with two methods including heating (65°C) and adding 0.5% formaldehyde by considering low destroying effect on hemagglutination (HA) and HI titers. The EDSV HI titers of 310 sera and 100 yolks obtained from 23 chicken farms ...

متن کامل

Comparison of a simple latex agglutination test with hemolysis-in-gel, hemagglutination inhibition, and radioimmunoassay for detection of rubella virus antibodies.

Rubella virus antibodies were measured in 300 sera from pregnant women visiting a maternity center by using a new, simple latex test, Rubalex. The results were compared with those obtained by using hemolysis in gel, hemagglutination inhibition, and radioimmunoassay. The sensitivity of the latex test was 100, 98.0, and 99.6% when compared with hemolysis in gel, hemagglutination inhibition, and r...

متن کامل

Identification of different measles virus-specific antibodies in the serum and cerebrospinal fluid from patients with subacute sclerosing pancencephalitis and multiple sclerosis.

Matched serum and cerebrospinal fluid (CSF) samples from eight cases of subacute sclerosing panencephalitis (SSPE) and 15 cases of multiple sclerosis (MS) were characterized in neutralization, hemolysis-inhibition (HLI), hemagglutination-inhibition (HI) with Tween 80-ether-treated antigen, complement-fixation (CF), and immunodiffusion tests. CF tests were carried out with crude virus material, ...

متن کامل

Simple procedure for the removal of nonspecific inhibitors of rubella virus hemagglutination.

The adsorption of serum lipoproteins onto an insoluble matrix of colloidal silicic acid results in the removal of nonspecific inhibitors of rubella virus hemagglutinin. The procedure can be performed in 15 min at room temperature. Comparative studies using both the dextran sulfate-CaCl2 and heparin-MnCl2 methods for removal of inhibitors demonstrated that the colloidal silicic acid procedure yi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012