Ingrowths of a percutaneously implanted aortic valve prosthesis (corevalve) in a patient with severe aortic stenosis.
نویسندگان
چکیده
An 80-year-old woman was admitted to our institution because of shortness of breath (New York Heart Association grade III) and stable angina pectoris (Canadian Cardiovascular Society [CCS] grade II). Two years ago, the patient had a posterior wall infarction successfully treated by percutaneous coronary intervention and stent implantation. A low-gradient aortic stenosis with an aortic valve area of 1.1 cm was also diagnosed but was considered to be clinically insignificant at the time. Because of the progression of symptoms within the last 2 years, a re-evaluation of coronary and aortic valve disease was performed. Coronary angiography revealed a 1-vessel coronary disease with a patent stent in the right coronary artery without any evidence of restenosis. The left ventricular ejection fraction was only moderately impaired (55%). However, the aortic valve area, as determined invasively, had decreased to 0.5 cm. This was confirmed by echocardiography; the cusps of the aortic valve were calcified and their motion was impaired (Supplemental Data Movie 1). On the basis of these findings, the necessity of an aortic valve replacement was discussed. However, because the patient was anxious and refused conventional aortic valve replacement, percutaneous treatment of the aortic stenosis using the second generation of the CoreValve ReValving system (CoreValve Inc, Irvine, Calif) was proposed1 (Figure 1A). This prosthesis has an inner diameter of 23 mm and consists of a self-expanding nitinol frame, which carries 3 leaflets of porcine pericardial tissue. The upper part of the frame anchors the system in the aorta; the middle part of the prosthesis is constrained to avoid interference with the coronaries and carries the valve. The lower part of the stent exerts high radial forces (which pushed aside the calcified leaflets), avoids recoil, and is covered with pericardium to minimize paravalvular leaks.1 Under general anesthesia and extracorporeal circulatory support, a valvuloplasty was performed, followed by successful CoreValve implantation via a transfemoral access (Supplemental Data Movies 2 and 3). The patient was extubated the same day, recovered quickly after the procedure, and left the hospital 10 days later. At 1-year follow-up, the mean gradient across the valve was 3 mm Hg, the aortic valve area was 1.7 cm, and there was no evidence of paravalvular leak (Supplemental Data Movie 4). These changes in hemodynamics were accompanied by an improvement in symptoms in this patient. Despite the increasing use of percutaneous aortic valve replacement, little is known about ingrowths of prostheses and durability in humans.1–3 The autopsy of our patient, who unfortunately committed suicide 425 days after implantation, might give some insight with regard to the CoreValve prosthesis. The calcified native valve was pushed aside by the CoreValve frame, and neither the native cusps nor the implanted bioprosthesis had any interference with the coronaries (Figure 2A). The bioprosthetic valve did not show any signs of morphological deterioration at autopsy (Figures 1B and 2B). The lower part of the stent, which was covered by porcine pericardium (Figure 1A) and positioned in the left ventricular outflow tract, was completely enclosed by fibromyoblasts (Figures 1B, 3A, and 3B). The ingrowths of the stent in the left ventricular outflow tract might explain why paravalvular leaks that are evident immediately after implantation disappear over time.1 Conversely, in the ascending aorta, only those struts of the frame that had close contact to the aortic wall were covered by endothelium (Figures 1B and 2A). All other parts of the frame, in particular the struts at the top, which extended into the aorta, had a surface without discoloration (Figures 1B and 2A). Despite the high flow velocity in the aorta, these nonendothelialized and noncovered parts of the nitinol frame might be a place of origin for thrombi formation and thromboembolic events. Therefore, platelet inhibition for 1 year after CoreValve implantation might be considered.
منابع مشابه
Incidence and management of CoreValve dislocation during transcatheter aortic valve implantation.
BACKGROUND Transcatheter aortic valve implantation is a highly specialized technique offering a new therapeutic option to patients at high risk for conventional surgery. Complications associated with this catheter procedure differ from complications after surgical aortic valve replacement. This is to report incidence, management, and impact on morbidity and mortality of CoreValve dislocation du...
متن کاملTechnical challenge of transfemoral aortic valve implantation in a patient with severe aortic regurgitation.
Transfemoral aortic valve implantation (TAVI) has become an important interventional technique for patients with severe aortic stenosis (AS) and very high surgical risks. Several studies have demonstrated the feasibility and clinical success of TAVI procedures.1,2 Indications of transfemoral implantations of aortic valves are clearly defined, and TAVI should only be performed in patients with s...
متن کاملPercutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.
This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, an...
متن کاملNext-generation transcatheter aortic valves. An opportunity to expand therapeutic indications?
Interventional cardiologists have spent years working on and dreaming about transcatheter aortic valve implantation. In 20072008 we were privileged in Spain to use 2 of the most commonly-implanted devices at the time: the Cribier-Edwards aortic valve prosthesis and the CoreValve self-expanding prosthesis. These devices had successful initial results in highsurgical-risk patients with severe aor...
متن کاملPercutaneous treatment of a dysfunctional aortic bioprosthesis with the CoreValve(®) prosthesis.
Recently, percutaneous aortic valve replacement has emerged as a therapeutic option for patients with severe symptomatic aortic stenosis and a high surgical risk. We report our initial experience in four patients with percutaneous implantation of a CoreValve aortic prosthesis to treat aortic bioprosthesis dysfunction involving aortic stenosis or regurgitation. In-hospital and medium-term outcom...