Agreement of Immunoassay and Tandem Mass Spectrometry in the Analysis of Cortisol and Free T4: Interpretation and Implications for Clinicians

نویسندگان

  • Rochelle E. Tractenberg
  • Jacqueline Jonklaas
  • Steven J. Soldin
چکیده

Objective. To quantify differences in results obtained by immunoassays (IAs) and tandem mass spectrometry (MSMS) for cortisol and free thyroxine (FT4). Design & Patients. Cortisol was measured over 60 minutes following a standard ACTH stimulation test (n = 80); FT4 was measured over time in two cohorts of pregnant (n = 57), and nonpregnant (n = 28) women. Measurements. Samples were analyzed with both IA and MSMS. Results. Results for cortisol by the two methods tended to agree, but agreement weakened over the 60-minute test and was worse for higher (more extreme) concentrations. The results for FT4 depended on the method. IA measurements tended to agree with MSMS measurements when values fell within "normal levels", but agreement was not constant across trimester in pregnant women and was poorest for the extreme (low/high) concentrations. Correlations between MSMS measurements and the difference between MSMS and IA results were strong and positive (0.411 < r < 0.823; all P < .05). Conclusions. IA and MSMS provide different measures of cortisol and FT4 at extreme levels, where clinical decision making requires the greatest precision. Agreement between the methods is inconsistent over time, is nonlinear, and varies with the analyte and concentrations. IA-based measurements may lead to erroneous clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Analysis of Metabolite Residues from Degradation of Dithiocarbamates in Cereals Using Liquid Chromatography Coupled with Tandem Mass Spectrometry

Background and Objectives: Dithiocarbamates are groups of fungicides used to control pests of agricultural products. Analysis of these pesticides with liquid and gas chromatography instruments is associated with various problems due to the presence of metal groups in the structure of these compounds. Therefore, one of the ways for analysis the pesticides is to check the level of decomposition...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Proteome analysis of Cryptosporidium parvum and C. hominis using two-dimentional electrophoresis, image analysis and tandem mass spectrometry

Until recently, Cryptosporidium was thought to be a single species genus. Molecular studies now showthat there are at least 10 valid species of this parasite. Among them, two morphologically identical species, C.hominis and C. parvum are the most pathogenic identified to date and share 97% of identical genomes.Post-genomic analyses is therefore necessary to explore further the...

متن کامل

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010