Improvements in MR angiography using phase-corrected data sets.

نویسندگان

  • T L Chenevert
  • K P Fechner
  • D Y Gelblum
چکیده

The objective of this work is refinement of an MR angiography technique via postprocessing removal of phase errors which inhibit static signal subtraction. Projective views of the object are obtained using interleaved flow-compensated and noncompensated gradient waveforms. Complex subtraction of data sets is required since a projection dephase pulse is used for static signal suppression. This renders the difference image susceptible to systematic phase errors which are modeled as a smoothly varying multiplicative phase function. The error function is estimated by comparison of heavily spatial filtered renditions of the object acquired without projection dephasing in order to minimize influence of flow. The phase correction is then applied to high-resolution data sets collected with projection dephasing to enhance flow sensitivity. The technique is demonstrated by improvement of MR angiograms of rats acquired on a 2-T, 31-cm-bore system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase-enhancement Technique for a Hybrid-of-opposite-contrast Mr Angiography

Introduction: A Flow-sensitive black-blood (FSBB) technique employing to 3D gradient echo (GRE) with motion-probing-gradient [1], and a MRA technique named Hybrid-of-opposite-contrast (HOP) MR angiography combining TOF and FSBB using dual-echo 3DGRE [2] were proposed. In addition, basic idea for correcting wraparound signal in vessels using phase-corrected real signal in FSBB was also proposed ...

متن کامل

طراحی پروتکل MR انژیوگرافی اندام تحتانی با استفاده از دستگاه 1.5MRI تسلا

Background and purpose: Ôn time diagnosis and treatment of lower limb diseases are of crucial importance to the patients. Çonventional angiography is the standard procedure of diagnosis, which is followed by different problems such as, X-ray hazards, sensitivity to contrast drugs and complications of opening vessel. Doppler ultrasonography has low differentiation power. MR angiography is a s...

متن کامل

Velocity-coded color MR angiography.

We developed a method of velocity-coded color MR angiography using a color code from the data obtained from velocity-phase images of phase-contrast MR angiography in order to add flow direction information to MR angiograms. Phase-contrast MR angiography with reconstruction of velocity-phase images was performed in 30 patients. Two projection images from velocity-phase images of each phase-contr...

متن کامل

Diagnostic Accuracy of Different Image Postprocessing Methods for the Detection of Coronary Artery Stenoses by Using Contrast Enhanced Coronary MRA at 3.0T

Introduction: Contrast enhanced 3T whole heart coronary MR angiography (CMRA) is a reliable method for the detection and exclusion of hemodynamically significant coronary stenosis and has shown high accuracy in recent single center trial. Whole heart coronary MR angiography has been introduced as a method that can provide visualization of long segments of all coronary arteries with a single 3D ...

متن کامل

A pitfall in detection of intracranial unruptured aneurysms on three-dimensional phase-contrast MR angiography.

We report three cases of intracranial unruptured aneurysm evaluated with MR angiography using both three-dimensional time-of-flight and three-dimensional phase-contrast techniques. It has been said that the phase-contrast technique has advantages over the time-of-flight technique in the detection of intracranial aneurysms. However, in our three cases, three-dimensional time-of-flight MR angiogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 1989