One-Stage External Fixation Using a Locking Plate: Experience in 116 Tibial Fractures.

نویسندگان

  • Jingwei Zhang
  • Nabil A Ebraheim
  • Ming Li
  • Xianfeng He
  • Jiayong Liu
چکیده

The authors report the results of 1-stage external fixation using a locking plate in 116 tibial fractures (85 closed and 31 open). The patients were followed for an average of 22 months. The mean duration of surgery was 42 minutes. The mean fracture healing time was 12 weeks for proximal, 20 weeks for shaft, 14 weeks for distal, and 24 weeks for multisegmental tibial fractures. Nonunion, deep infection, and breakage of screws did not occur. External plate fixation is effective for tibial fractures and especially for metaphyseal fractures. It has the advantages of being easy to perform and less invasive, and the plate is conveniently located for removal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal tibial fracture: An ideal indication for external fixation using locking plate

OBJECTIVE To evaluate the feasibility and efficiency of one-stage external fixation by using locking plate in distal tibial fractures. METHODS In this non-control prospective study, 28 patients with distal tibial fractures were included and underwent one-stage external fixation by using locking plate. There were 21 males and 7 females, with a mean age of 43 years (19-63). According to AO/OTA ...

متن کامل

Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.

OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the fo...

متن کامل

External Fixation Using Femoral Less Invasive Stabilization System Plate in Tibial Proximal Metaphyseal Fracture

BACKGROUND The locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed fractures. The purpose of this study is to evaluate the results of external fixation using the femoral less invasive stabilization system (LISS) plate in proximal metaphyseal fractures of the tibia. MET...

متن کامل

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. M...

متن کامل

Multifragmentary Tibial Pilon Fractures: Midterm Results After Osteosynthesis with External Fixation and Multiple Lag Screws

Osteosynthesis of intraarticular tibial pilon fractures is preferably achieved using locking plates via a minimally invasive technique. If combined with severe soft tissue damage there is a high risk of wound-healing deficits after plate osteosynthesis. Thus our aim was to find an alternative method of treatment for those cases with combined soft tissue injuries.We report on five cases with com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 8  شماره 

صفحات  -

تاریخ انتشار 2015