Factors influencing normal reference intervals for creatinine, urea, and electrolytes in plasma, as measured with a Beckman Astra 8 Analyzer.
نویسندگان
چکیده
In a study of 514 healthy adults, we used a Beckman Astra 8 Analyzer to establish normal reference intervals for plasma creatinine, urea, and electrolytes. For potassium and chloride these were considerably lower and higher, respectively, than previously reported ranges. All of these analytes showed significant sex-related differences; all except chloride showed age-related changes. The relationship of these biochemical indices to fasting, cigarette smoking, alcohol intake, regular exercise, and the contraceptive pill--independent of these age- and sex-related differences--was assessed by multiple linear regression. The effect was significant in each case. Our results underline the importance of regular review of reference values.
منابع مشابه
Measurement of urinary constituents with the Astra-8 Multichannel Analyzer.
The Beckman Astra-8 is a computerized, discrete-microsample, multiple-test clinical chemistry analyzer. We have examined its capability to measure urine Na+, K+, Cl-, urea nitrogen, glucose, and creatinine and found that (a) the Astra measurements are linear, accurate, and precise in concentration ranges of urine analytes; (b) urine analyte concentrations measured with the Astra correlate well ...
متن کاملEvaluation of a new multichannel analyzer, "Astra-8".
We evaluated a new multiple-channel chemistry analyzer, the Beckman "Astra-8," which is controlled by a microprocessor with 52K bytes of memory. The instrument we tested performed the following tests: Na, K, CO2, chloride, urea nitrogen, glucose, and creatinine. We compared the Astra-8 to a continuous-flow (SMA 6/60) and a discrete (Du Pont aca, urea nitrogen only) analyzer. The Astra-8 demonst...
متن کاملFactitiously high sodium activities on the Ektachem 400 owing to interferences by high gamma-globulin concentrations.
Sera from patients with above-normal gamma-globulin concentrations give sodium values as much as 10% higher when measured in the Kodak Ektachem 400 analyzer than results obtained with the Beckman Astra-8 analyzer. Results obtained with the Astra were in agreement with flame photometry. A similar relative bias was observed for potassium measurement in the Ektachem. This discrepancy was corrected...
متن کاملNotes for Contributors
had been unused for some time within the calibration period could give erroneously low results. This was most likely to happen if a series of urine samples were analysed followed by a serum, but the .effect was by no means reproducible. The manufacturer is aware of this problem, which is probably caused by deterioration of the reagent in the measuring cup, and is taking steps to correct it. Cre...
متن کاملEvaluation of the effect of exercise on serum creatinine and urea nitrogen in hemodialysis patients
Introduction. Chronic renal failure is a progressive disease in which kidney function is impaired, so that the body can not metabolize and maintain fluid balance and electrolytes. Therefore, the present study investigated changes in serum creatinine and urea nitrogen in hemodialysis patients in response to exercise. Materials and Methods. The subjects of this study were dialysis patients who we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 31 2 شماره
صفحات -
تاریخ انتشار 1985