Model-Based Generic Approaches For Automated Fault Detection, Diagnosis, Evaluation (FDDE) And for Accurate Control of Field-Operated Centrifugal Chillers

نویسندگان

  • Yongzhong Jia
  • Nicholas Cernansky
  • Bakhtier Farouk
  • Alan Lau
  • Ajmal Yousuff
چکیده

Model-Based Generic Approaches for Automated Fault Detection, Diagnosis, Evaluation (FDDE) And Accurate Control of Field-Operated Centrifugal Chillers Yongzhong Jia Agami Reddy Performance monitoring of large engineering systems with the objective of optimal control and fault detection, diagnosis and evaluation (FDDE) has drawn the attention of several researchers over the last 3-4 decades. However, there are several fundamental and applied issues that need to be researched into, evaluated, developed and tested before it can be used with confidence by the professional HVAC&R community. This research will specifically address: (i) the issue of automated FDDE for large vapor compression chillers by developing a generic (i.e., one which can be used for any vapor compression centrifugal chiller) model-based (as against model-free) approach that provides diagnostic insight into which primary chiller component is not performing as designed and has developed a fault, and (ii) provide accurate chilled water temperature control for vapor compression chillers by developing a transient physical model-based feed-forward control configuration (as against the traditional feed-back control configuration applied in centrifugal chillers). A primary and distinctive facet of this approach is that this FDDE methodology and new control strategy will be based as much as possible on using existing sensors, transducers, and other hardware rather than requiring that these be installed specifically for this purpose. Each and every primary component of the chiller can be characterized by at least one performance parameter, the magnitude of which is indicative of the health of that component. Mathematical models for these characteristic parameters are presented, and how well these models can be trained with field-monitored data is illustrated. Large chillers are usually controlled by inlet guide vanes, which vary the refrigerant temperature in the evaporator. For such a control to respond quickly while maintaining reasonable accuracy, the guide vanes must be directly commanded by a function associated with the input signal. A transient physical model has been developed analytically, calibrated and validated against one-minute chiller transient data. Test results show that this new control strategy improves the control accuracy by 28% under the operating conditions selected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Fault Detection and Isolation Method Based on Belief Rule Base for Industrial Gas Turbines

Real time and accurate fault detection has attracted an increasing attention with a growing demand for higher operational efficiency and safety of industrial gas turbines as complex engineering systems. Current methods based on condition monitoring data have drawbacks in using both expert knowledge and quantitative information for detecting faults. On account of this reason, this paper proposes...

متن کامل

Robust Model- Based Fault Detection and Isolation for V47/660kW Wind Turbine

In this paper, in order to increase the efficiency, to reduce the cost and to prevent the failures of wind turbines, which lead to an extensive break down, a robust fault diagnosis system is proposed for V47/660kW wind turbine operated in Manjil wind farm, Gilan province, Iran. According to the acquired data from Iran wind turbine industry, common faults of the wind turbine such as sensor fault...

متن کامل

Simulation-based Vibration Sensor Placement for Centrifugal Pump Impeller Fault Detection

In this paper, a simulation-based method is proposed for optimal placement of vibration sensors for the purpose of fault detection in a centrifugal pump. The centrifugal pump is modeled to investigate the effect of vane tip fault on fluid flow patterns numerically. Pressure pulsations are investigated at different locations at the inner surface of the pump before and after the presence of the f...

متن کامل

Variable Speed Wind Turbine DFIG Back to Back Converters Open-Circuit Fault Diagnosis by Using of Combiniation Signal-Based and Model-Based Methodes

Condition monitoring (CM) and Fault Detection (FD) of wind turbine lead to increase in reliability and availability of turbine. IGBT open circuit of wind turbine converter will bring about depletion in output current of converter and as a result, reduction in production of wind turbine power. In this research, back to back converter IGBT open - gate fault for wind turbine based on DFIG is detec...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002