A study of coagulation mechanisms of polyferric sulfate reacting with humic acid using a fluorescence-quenching method.

نویسندگان

  • Wen Po Cheng
  • Fung Hwa Chi
چکیده

A fluorescence-quenching method is developed to assess the effect of pH on the coagulation mechanism of humic acids (HA) reacting with metal ions. A polyferric sulfate (PFS) synthesized in our laboratory is adopted as the coagulant to simplify the hydrolysis process and increase the experimental precision. The following results are discovered. When the concentration of PFS increases from 2 to 10 mg/L, the effective pH range of HA removal changes from 4.0-5.0 to 4.0-7.5. At increased coagulation pH, the ferric ions may still react with HA but unable to neutralize the surface charge completely. The residual concentrations of HA measured by fluorescence spectrophotometer are lower than those by TOC, as a consequence of the fluorescence-quenching effect. This demonstrates that the coagulation of HA by PFS at low pH is mainly due to charge-neutralization. The adsorption of the HA on the pre-formed iron hydroxide flocs is accompanied by the dissociation of Fe ions from the floc structure until the equilibrium has been reached, which is evidenced by the presence of the Fe-HA complexes in the solution during adsorption experiment. This is quite different from the characteristics of flocs formed by PFS associated with HA in the coagulation. Within the pH range investigated, the complex-formation and the hydrolysis are the two competitive reactions happened between the hydroxide ions in solution and the functional groups of HA. Therefore, the removal of HA is not caused by adsorbing onto the iron hydroxide resulted from PFS hydrolysis, but through the complex-formation between the PFS and the HA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Different Electrodes on Humic Acid Removal by Electrocoagulation

The present study is about the reduction of humic acids (HA) by electrocoagulation (EC) method. Undesirable color, odor, taste, reacting with chlorine to produce toxic materials in water, and making a complex with heavy metal ions are some unfavorable environmental consequences of HA. Platinum and graphite as anode electrodes and platinum, titanium, and aluminum as cathode electrodes were used ...

متن کامل

Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO43- and SiO32- Modifiers

PO4(3-) and SiO3(2-) are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants--polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their s...

متن کامل

بررسی اثر منعقدکننده ها در حذف CODوTSS شیرابه زباله کارخانه کمپوست اصفهان

Introduction: Untreated leachate is being discharged into the environment in many countries worldwide. Leachate treatment methods have not been unified so far due to variable composition of leachate in different sites. Lack of control as well as disregarding leachate treatment and disposal of it can cause environmental pollution. This study aimed to investigate the Coagulants' effect on the COD...

متن کامل

The simultaneous removal of turbidity and humic substances from water using the enhanced coagulation process

This study aimed to investigate the efficiency of the enhanced coagulation (EC) process for the simultaneous removal of turbidity and humic substances (HS) from raw water from the Sanandaj Water Treatment Plant (SWTP). This study was conducted on a laboratory scale using a jar test device and ferric chloride (FeCL3) as the coagulant. Accordingly, the effects of pH and coagulant dosag...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Water research

دوره 36 18  شماره 

صفحات  -

تاریخ انتشار 2002