Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow.

نویسندگان

  • Dorothea I Hollnagel
  • Paul E Summers
  • Spyros S Kollias
  • Dimos Poulikakos
چکیده

PURPOSE To verify the accuracy of velocity mapping with three-dimensional (3D) phase-contrast magnetic resonance angiography (PC-MRA) for steady flow in a realistic model of a cerebral artery aneurysm at a 3T scanner. MATERIALS AND METHODS Steady flow through an original geometry model of a cerebral aneurysm was mapped at characteristic positions by state-of-the-art laser Doppler velocimetry (LDV) as well as 3D PC-MRA at 3T. The spatial distributions and local values of two velocity components obtained with these two measurement methods were compared. RESULTS The 3D PC-MRA velocity field distribution and mean velocity values exhibited only minor differences to compare to the LDV measurements in straight artery regions for both main and secondary velocities. The differences increased in regions with disturbed flow and in cases where the measurement plane was not perpendicular to the main flow direction. CONCLUSION 3D PC-MRA can provide reliable measurements of velocity components of steady flow in small arteries. The accuracy of such measurements depends on the artery size and the measurement plane positioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

In vitro validation of flow measurement with phase contrast MRI at 3 tesla using stereoscopic particle image velocimetry and stereoscopic particle image velocimetry-based computational fluid dynamics.

PURPOSE To validate conventional phase-contrast MRI (PC-MRI) measurements of steady and pulsatile flows through stenotic phantoms with various degrees of narrowing at Reynolds numbers mimicking flows in the human iliac artery using stereoscopic particle image velocimetry (SPIV) as gold standard. MATERIALS AND METHODS A series of detailed experiments are reported for validation of MR measureme...

متن کامل

Non-contrast enhanced MR angiography: physical principles.

Noncontrast-enhanced magnetic resonance angiography (NCE-MRA) methods have been demonstrated in anatomies throughout the body. Previously established NCE-MRA techniques suffered from long scan times or low sensitivity. Advances in hardware and software have made NCE-MRA scan times clinically feasible. Recent concerns over the safety of gadolinium-based contrast material combined with the expens...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

Quantification of Blood Flow in Internal Cerebral Artery by Optical Flow Method on Digital Subtraction Angiography in Comparison with Time-Of-Flight Magnetic Resonance Angiography

OBJECTIVE This study compared data on the blood flow velocity in the internal carotid artery, which was obtained using the optical flow method (OFM) with digital subtraction angiography (DSA) and the time-of-flight (TOF) technique using magnetic resonance angiography (MRA). MATERIALS AND METHODS Images were obtained from 12 cerebrovascular patients who underwent both brain DSA and MRA imaging...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2007