Handheld modern computer brings new features to portable X-ray fluorescence coating thickness measurement device
نویسندگان
چکیده
In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier's archiving and manuscript policies are encouraged to visit: a r t i c l e i n f o a b s t r a c t X-ray fluorescence is routinely used to measure coating thickness on table top setup. The use of a handheld modern computer (PC compatible) gives the possibility to build a portable device with new features. The computer is used to control device's components and to do processor consuming calculation. The user interface is " push button " to allow the utilization by nonspecialized operator.
منابع مشابه
کاربرد دستگاه XRF پرتابل در مطالعات باستانسنجی مواد فرهنگی تاریخی
Study of cultural and historical materials excavated from the archaeological excavation is one of the most important goals of Archaeometry, in order to answer a lot of questions in archaeology. In this regard, elemental analysis is important factors in the realization of this aim. Numerous analytical methods have been used for this purpose traditionally. Among them, X-ray fluorescence spectrosc...
متن کاملInvestigation and Measurement of Ash Content of Coal in Zirab Coal Mine-Iran Using Dual Energy -Ray and X-Ray Fluorescence Methods
Coal with low ash content has an important role in the coal and steel industry. There are different methods to measure the ash content. The conventional method which is used in most coal mines of Iran, is to burn the coal and measure the remaining ash. A new method has been recently developed at Nuclear Research Center (NRC) of Iran, Which works on the basis of the absorption of the dual en...
متن کاملNew electrical device for field coincidence quality control test in linear accelerators
Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...
متن کاملRecent Developments in Handheld X-ray Fluorescence (XRF) Instrumentation
RECENT DEVELOPMENTS IN HANDHELD X-RAY FLUORESENCE INSTRUMENTATION The introduction of new large area silicon drift detectors to handheld XRF technology expands technique capabilities with greater analytical range and lower detection limits James Pasmore, Director, Business Development [email protected] Thermo Niton Analyzers LLC Thermo Fisher Scientific 900 Middlesex Turnpike, Buil...
متن کاملNew Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators
Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computer Physics Communications
دوره 182 شماره
صفحات -
تاریخ انتشار 2011