Distribution Grid Fault Location Applying Transient Zero-mode Current
نویسندگان
چکیده
To aim at the puzzles on faults location in distribution grids, the paper analyzed the distributing characteristics of transient zero-mode currents as the faults occurred, with the aid of correlation theory, a new fault circuit-selection and fault-location method was proposed based on transient zero model current for power distribution grid faults. The method is based on such a fact that the RMS was maximum of fault line transient zero-mode current, and the inner products between it and other line transient zero-mode current were less than zero, in addition, the transient zero-model currents at two sides of the fault point possessed opposite polarity and diverse waveform, and as well as small correlation coefficient closer to zero. In the end, the simulation results show that the proposed method on circuit-selection and faultlocation for power distribution grids fault based on transient zeromode current is correct and effective, and not affected by voltage epoch angle, and grounding resistance, and as well as neutral-point grounding modes.
منابع مشابه
Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملSelection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملA New Fast and Accurate Fault Location and Classification Method on MTDC Microgrids Using Current Injection Technique, Traveling-Waves, Online Wavelet, and Mathematical Morphology
In this paper, a new fast and accurate method for fault detection, location, and classification on multi-terminal DC (MTDC) distribution networks connected to renewable energy and energy storages presented. MTDC networks develop due to some issues such as DC resources and loads expanding, and try to the power quality increasing. It is important to recognize the fault type and location in order ...
متن کاملSymmetric Components for Transient Regime Application in MV Systems
In order to apply advantageously the symmetrical components theory to SLG fault transients in distribution systems we take profit of similitude of transient components in faulty phase current and in zero sequence current on faulty feeder. Then we are able to take into account the load current contribution within voltage drop account of zero sequence equivalent circuit. The result is an Extended...