Effect of compensation for scattering angular uncertainty in analytical Compton camera reconstruction.
نویسندگان
چکیده
In Compton cameras, the measured scattering angle is associated with an uncertainty which becomes larger as the incident gamma-ray energy decreases. Since this uncertainty degrades the spatial resolution of reconstructed images, Hirasawa and Tomitani (2003 Phys. Med. Biol. 48 1009-26) previously revised their analytical reconstruction algorithm to compensate for it. As the new algorithm improved the spatial resolution in effect, they expected an enhancement of the statistical noise. In this paper, the effect of this compensation has been analysed in view of spatial resolution (the FWHM of the noise-free reconstructed image for a point source distribution), statistical noise (the relative standard deviation of reconstructed images for an isotropic source distribution) and image quality (the roughness of reconstructed images for a phantom). The results describe not only the effect of the compensation, but also the relation between the statistical noise and three parameters, i.e., the incident gamma-ray energy, the spatial resolution and the measured total event numbers, in reconstruction with compensation. This relation should be taken into account for the design of Compton cameras with good quality images, i.e., useful image, output.
منابع مشابه
Camera Arrangement in Visual 3D Systems using Iso-disparity Model to Enhance Depth Estimation Accuracy
In this paper we address the problem of automatic arrangement of cameras in a 3D system to enhance the performance of depth acquisition procedure. Lacking ground truth or a priori information, a measure of uncertainty is required to assess the quality of reconstruction. The mathematical model of iso-disparity surfaces provides an efficient way to estimate the depth estimation uncertainty which ...
متن کاملList Mode EM Reconstruction of Compton Scatter Camera Images in 3-D1
A method has been developed for List Mode EM reconstruction of Compton scattering camera images in 3-D, using a previously reported 2-D technique and refining and adapting it to three dimensions. Spatial variation in the system sensitivity is determined by an approximate numerical integration which accounts for solid angle effects, absorption and escape probabilities, and variation in the diffe...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملTowards direct reconstruction from a gamma camera based on Compton scattering
The Compton scattering camera (sometimes called the electronically collimated camera) has been shown by others to have the potential to better the photon counting statistics and the energy resolution of the Anger camera for imaging in SPECT. By using coincident detection of Compton scattering events on two detecting planes, a photon can be localized to having been sourced on the surface of a co...
متن کاملEvaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors
A CZT Compton Camera (CCC) is being built using two three-dimensional (3-D) position-sensitive CZT detectors. Expected system performance was analyzed by analytical and Monte Carlo approaches. Based on the measurement of detector energy and position resolution, the expected angular resolution is &33 and &23 for a $303 FOV for 511 keV and 1 MeV c-rays, respectively. The intrinsic e$ciency for a ...