Agreement and error rates using blinded review to evaluate surgical pathology of biopsy material.

نویسندگان

  • Andrew A Renshaw
  • Norberto Cartagena
  • Scott R Granter
  • Edwin W Gould
چکیده

Blinded review has been shown to be an excellent method to detect disagreements and errors and improve performance in gynecologic cytology. Preliminary studies suggest it may be valuable in surgical pathology. We reviewed 5,000 sequential outpatient surgical pathology biopsy cases without knowledge of the original diagnosis or history and compared the results with those of the original diagnosis. Complete agreement was obtained in 91.12% of cases. The technique of blinded review of surgical pathology biopsy material had a sensitivity of more than 99%, failing to identify an abnormality in 19 cases. Although there was a significant level of diagnostic disagreement (444 cases), primarily due to differences in diagnostic thresholds (292 cases), diagnoses that resulted in a change in the original report (true errors) were present in only 5 cases, and only 4 were clinically significant. This clinically significant error rate of 0.08% is significantly lower than previously published error rates. Blinded review is a sensitive (99%) and effective method to identify areas of disagreement and errors in surgical pathology biopsy material. The relatively high rate of disagreement found with blinded review coupled with the very low rate of error highlights the substantial potential for bias in nonblinded reviews.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of disagreement and amendment rates by tissue type and diagnosis: identifying cases for directed blinded review.

We sought to determine whether a group of cases that was relatively high in disagreements and subsequent amendments could be identified and targeted for blinded review. During a 4-year period, 8,916 surgical pathology and nongynecologic cytology cases were subjected to blinded review; of these, there were 616 disagreements (6.9%), 69 (0.8%) had subsequent amendments issued, and 33 (0.4%) repres...

متن کامل

Correlation of workload with disagreement and amendment rates in surgical pathology and nongynecologic cytology.

In gynecologic cytology, workload limits are imposed as a surrogate to limit error rates. Whether workload correlates with error rates in surgical pathology and nongynecologic cytology is not known. We reviewed and compared the disagreement and amendment rates based on blinded review for 5 pathologists with the number of cases reviewed during that same period. A total of 2,659 general surgical ...

متن کامل

A Review of Biopsy in Dentistry: Principles, Techniques, and Considerations

Biopsy is a useful technique for definitive diagnosis of abnormal oral conditions and it must be performed carefully since any error may result in histopathologic misidentification of the lesion. Present study evaluated the most relevant literatures published between 1982 and 2012 in order to review existed guidelines of correct biopsy performance using scientific database sources such as PubMe...

متن کامل

Anatomic Pathology / MEASURING AND REPORTING ERRORS IN SURGICAL PATHOLOGY

Substantial improvements in measuring and reporting errors in gynecologic cytology have been made during the last decade. Measuring and reporting errors in surgical pathology recently has gained renewed interest. However, review of current literature demonstrates mistakes in how these data are measured and reported. Error rates have been reported from review of consecutive material, biopsy mate...

متن کامل

Interobserver variations in reporting of prostatic adenocarcinoma using core biopsy specimens: a retrospective study from a tertiary referral hospital in Saudi Arabia.

In recent years, greater numbers of prostate biopsy cores are being submitted for histopathological assessment, with a concomitant increase in workload for the pathologist. This retrospective study aimed to assess the concordance and interobserver variation between histopathologists in reporting prostatic adenocarcinoma using material obtained from prostatic core biopsy specimens. A total of 81...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 119 6  شماره 

صفحات  -

تاریخ انتشار 2003