Freehand Ultrasound Reconstruction Based on ROI Prior Modeling and Normalized Convolution
نویسندگان
چکیده
3D freehand ultrasound imaging is becoming a widespread technique in medical examinations. This imaging technique produces a set of irregularly spaced B-scans. Reconstructing a regular grid from these B-scans is a challenging problem that enables the visualization and further analysis of the acquired data. This paper focuses on extending an existing method [1] to define the output reconstruction grid based on principal component analysis (PCA). Our method introduces a model for the region of interest (ROI) in order to adapt the grid to the ROI. In addition, a technique based on normalized convolution is proposed for the interpolation problem. A new applicability function based on the correlation function of a linear probe is used to avoid inter-resolution cell blurring.
منابع مشابه
An Alignment-by-reconstruction Algorithm
In this paper we propose a reconstruction algorithm with alignment for free-hand 3D ultrasound. A set of ultrasound images with the associated positions and orientations are stored and used to reconstruct a given region of interest (ROI). In freehand ultrasound, the inspection planes are not parallel nor uniformly spaced. The proposed reconstruction algorithm deals with this non uniform samplin...
متن کاملProbe Localization for Freehand 3D Ultrasound by Tracking Skin Features
Ultrasound probe localization with respect to the patient's body is essential for freehand three-dimensional ultrasound and image-guided intervention. However, current methods for probe localization generally involve bulky and expensive equipment. In this paper, a highly cost-effective and miniature-mobile system is described for 6-DoF probe localization that is robust to rigid patient motion. ...
متن کاملReconstruction of freehand 3D ultrasound based on kernel regression
INTRODUCTION Freehand three-dimensional (3D) ultrasound has the advantages of flexibility for allowing clinicians to manipulate the ultrasound probe over the examined body surface with less constraint in comparison with other scanning protocols. Thus it is widely used in clinical diagnose and image-guided surgery. However, as the data scanning of freehand-style is subjective, the collected B-sc...
متن کاملUltrasound Guided Surgery: Image Processing and Navigation
The process of 3D freehand ultrasound acquisition consists of two steps: scanning and reconstruction. Prior to scanning, a position sensor is attached to the probe for tagging each image with its position and orientation in space. A crucial step prior to reconstruction and visualization is calibration of the ultrasound probe with the attached position sensor, i.e. determining the position and o...
متن کاملSurface Reconstruction from Sparse & Arbitrarily Oriented Contours in Freehand 3D Ultrasound
3D reconstruction for freehand 3D ultrasound is a challenging issue because the recorded B-scans are not only sparse, but also non-parallel (actually they may arbitrarily orient in 3D space and may intersect each other). Conventional volume reconstruction methods can’t reconstruct sparse data efficiently while not introducing geometrical artifacts and conventional surface reconstruction methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003