Drug-eluting stent implantation could be associated with long-term coronary endothelial dysfunction.

نویسندگان

  • Dong Il Shin
  • Pum Joon Kim
  • Ki-Bae Seung
  • Dong Bin Kim
  • Mi-Jeong Kim
  • Kiyuk Chang
  • Sung Min Lim
  • Doo Soo Jeon
  • Wook Sung Chung
  • Sang Hong Baek
  • Man Young Lee
چکیده

Drug-eluting stent (DES) implantation may be associated with endothelial dysfunction. However, changes in long-term endothelial function based on the type of DES remain largely unknown. We assessed coronary endothelial function after DES implantation compared to bare-metal stents (BMS) and determined the differences according to DES type. Patients who had single BMS or DES implantation in the left anterior descending artery and showed no restenosis in follow-up angiography at 6 to 9 months were assigned to the BMS group (5 patients) or DES group (9 sirolimus-eluting stents, SES, and 8 paclitaxel-eluting stents, PES). Endothelium-dependent vasomotion, after intracoronary infusion of acetylcholine, was determined by quantitative coronary angiography. Also, endothelium-independent vasomotion was assessed after nitrate infusion. In the distal and far distal segments, the SES (SES versus BMS, distal: -27.6 +/- 16.3% versus -0.6 +/- 1.6%; P = 0.01, far distal: -24.8 +/- 13.2% versus -0.9 +/- 1.3%; P = 0.02) and PES groups (PES versus BMS, distal: -25.4 +/- 17.1% versus -0.6 +/- 1.6%; P = 0.01, far distal: -26.6 +/- 15.9% versus -0.9 +/- 1.3%; P = 0.01) had similar patterns showing significant vasoconstriction compared with the BMS group. In addition, the DES group showed a significant reduction of diameter in distal (SES: P = 0.001, PES: P = 0.04) and far distal segments (SES: P = 0.002, PES: P = 0.001) compared with proximal and near proximal segments. However, the BMS group did not demonstrate significantly different vasomotion between proximal and distal segments. Vasodilatation by nitrate infusion was preserved in all subjects. SES or PES implantation could be associated with the similar pattern of endothelial dysfunction identified predominantly in the long distal portion of the treated vessel.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of drug-eluting stents on endothelial dysfunction

Drug-eluting stents are considered a breakthrough in the treatment of coronary artery disease owing to their ability to reduce rates of restenosis and the subsequent need for target lesion revascularization. The literature has limited reports of long-term results of drug-eluting stent implantation with respect to vascular integrity and coronary endothelial function. Thus, we review the currentl...

متن کامل

Endothelial dysfunction after drug eluting stent implantation.

Endothelial dysfunction has been implicated in the pathological process of coronary artery disease as well as an adverse event after coronary drug eluting stent (DES) implantation. In this review, an overview will be given of the evidence to date regarding the effects of coronary DES on endothelial function obtained from both clinical and experimental studies. Stenting in general and DES seem t...

متن کامل

Coronary endothelial dysfunction distal to stent of first-generation drug-eluting stents.

OBJECTIVES This study sought to evaluate the relationship between coronary endothelial function and neointimal coverage after drug-eluting stent (DES) implantation. BACKGROUND The mechanisms of endothelial dysfunction after DES implantation remain to be fully elucidated. We hypothesized that poor neointimal coverage after DES implantation may be associated with endothelial dysfunction distal ...

متن کامل

Response to letter regarding article, "the long-term effect of coronary stenting on epicardial and microvascular endothelial function".

We highly appreciate the letter regarding our recently published study on the long-term effect of stenting in patients presenting with chest pain, where Dr Kaneda and Dr Tarashima raised several important comments. Indeed, knowledge about the frequency of patients returning with symptoms after stent implantation, but no significant stenosis, would add interesting information and should be evalu...

متن کامل

Coronary Endothelial Dysfunction after Drug-Eluting Stent Implantation

Problem statement: Stent thrombosis, which may occur even one year after stent implantation, is a drawback of Drug-Eluting Stents (DES). Among the variety of causes of stent thrombosis after DES implantation, coronary endothelial dysfunction manifested or exaggerated by DES implantation should not be overlooked. This review article summarizes previous reports on coronary endothelial dysfunction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International heart journal

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2007