Consequences of tumor planning target volume reduction in treatment of T2-T4 laryngeal cancer

نویسندگان

  • Cornelia AJM Vugts
  • Chris HJ Terhaard
  • Marielle EP Philippens
  • Frank A Pameijer
  • Nicolien Kasperts
  • Cornelis PJ Raaijmakers
چکیده

BACKGROUND AND PURPOSE Since lymph nodes volumes are generally four times the volume of the primary PTV, the advantage of using tight margins around the primary PTV is not clear. Therefore treatment margins of T2-T4 laryngeal carcinoma for IMRT are generally chosen in such a way that the PTV is comparable to that in conventional radiotherapy. The aim of this study is to quantify the effect of volume reduction of the primary PTV of T2-T4 laryngeal carcinoma with regard to late toxicity despite elective irradiation of lymph node levels II to IV. METHODS Two treatment plans based on conservative (GTV-PTV = 15 mm and 20 mm cranial), and on evidence-based tight margins (GTV-PTV = 8 mm) were calculated for 16 patients. Toxicity effects were estimated based on the dose distributions. RESULTS Compared to conservative margins, using tight margins resulted in: 1) significant reduction of the normal tissue complication probability (NTCP) for swallowing muscles and submandibular glands, 2) significant reduction of the mean dose in all organs at risk (OAR), 3) a mean dose smaller than 60 Gy for all OARs except for the laryngeal cartilages. When the lymph node levels II to IV were prescribed with an elective dose, an NTCP reduction of 53% for the swallowing muscles and of 23% for the submandibular glands was found by using tight instead of conservative margins. When positive nodes were present, NTCP reduction amounted to 29% and 15%, respectively. CONCLUSIONS There is a potential benefit in realizing evidence-based tight margins for laryngeal cancer patients despite elective irradiation of lymph node levels II to IV.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

The Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer

Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...

متن کامل

Investigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy

Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels  on   CT  images  will  change   the   CT  numbers  and  electron   density   of   tissues, conse...

متن کامل

Evaluation of the effect of dental filling material on IMRT treatment planning in patient with nasopharyngeal cancer

Introduction: Presence of dental filling material (DFM) such as amalgam in treatment patient with nasopharyngeal cancer (NPC) is common. Streaking artifact Arising from this high density material in computed tomography (scan), may lead to perturbation in dose calculation and dose delivery. Widespread performance of intensity-modulated radiotherapy (IMRT) for NPC using anterior...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014