Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions.

نویسندگان

  • Stephen J Glick
  • Clay Didier
چکیده

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5-3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications

Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for th...

متن کامل

Spectrometric Performances of CdTe and CdZnTe Spectrometric Semiconductor Detector Arrays at High X-Ray Flux

The development of a novel energy resolved fast Xray imaging detector is reported. The device is based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) detectors coupled to a custom designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, a fast Analog to Digital Converter (ADC) continuously digitizes the signal from the detector pixel. A F...

متن کامل

The Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

متن کامل

A New X-ray Computed Tomography System for Laboratory Mouse Imaging

Two versions of a new high-resolution x-ray computed tomography system are being developed to screen mutagenized mice in the Oak Ridge National Laboratory Mammalian Genetics Research Facility. The first prototype employs a single-pixel cadmium zinc telluride detector with a pinhole collimator operating in pulse counting mode. The second version employs a phosphor screen/CCD detector operating i...

متن کامل

Recent Progress in CdTe and CdZnTe Detectors

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and γray detection. The high atomic number of the materials (ZCd =48, ZTe=52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ∼ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of cha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physics

دوره 114 14  شماره 

صفحات  -

تاریخ انتشار 2013