Determination of Capacitor Life as a Function of Operating Voltage and Temperature

نویسنده

  • David Evans
چکیده

Background Potentiostatically charged Hybrid capacitors age predictably by a mechanism involving electrochemical reactions that reduce the efficiency of the cathode and consume electrolyte. One of these reactions results in the formation of hydrogen at the cathode which reacts irreversibly with the tantalum foil substrate. The material formed is much less conductive than the original. The consequence to capacitor performance is an increase in ESR and a decrease in capacitance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grid Integration of a Single-Source Switched-Capacitor Multilevel Inverter with Boosting Capability

This paper investigates the connection of a single-phase multilevel inverter structure to an existing power grid. The applied voltage source inverter is able to generate a near sinusoidal voltage waveform with an amplitude six times the input voltage by using a single DC input power supply. A proportional-resonant (PR) controller regulates the injected current into the grid. While the EPLL is u...

متن کامل

A Novel Structure for Realization of a Pseudo Two Path Band-Pass Filter

In this paper, a modified auto zeroed integrator is used to design and simulate a low-voltage high-Q switched capacitor pseudo 2-path filter.  The filter is a sixth–order Chebyshev band-pass filter operating at sampling frequency of 1MHz and center frequency of 250 kHz with a quality factor of 50. The proposed filter has both low-voltage and high speed properties of the auto zeroed integrators ...

متن کامل

Multi Objective Allocation of Distributed Generations and Capacitor Banks in Simultaneous

This paper has developed a novel multiobjective function for optimal sizing and sitting ofDistributed Generation (DG) units and capacitor banks in simultaneous mode to improve reliabilityand reduce energy losses. The proposed function consists of four objectives: Cost of Energy NotSupplied (CENS), System Average Interruption Duration Index (SAIDI), costs of energy loss andinvestment. A novel st...

متن کامل

A Very Low Voltage 9th Order Linear Phase Baseband Switched Capacitor Filter (RESEARCH NOTE)

A very low voltage 9th order linear phase baseband switched capacitor (SC) filter has been designed to be used as part of a cellular GSM (Global System Mobile) receiver. A Gaussian-to-6dB filter of the order of seven is chosen and a second order function is added to reduce the group delay variations around. The filter uses a fully differential topology to increase the dynamic range and reduce t...

متن کامل

Multi-objective Based Optimization Using Tap Setting Transformer, DG and Capacitor Placement in Distribution Networks

In this article, a multi-objective function for placement of Distributed Generation (DG) and capacitors with thetap setting of Under Load Tap Changer (ULTC) Transformer is introduced. Most of the recent articles have paidless attention to DG, capacitor placement and ULTC effects in the distribution network simultaneously. Insimulations, a comparison between different modes was carried out with,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011