Parahisian Atrial Tachycardia: Cryoablation from the Aortic Cusp
نویسندگان
چکیده
A 29-year-old female patient with Ebstein anomaly was referred to our division for drugresistant symptomatic wide-complex tachycardia. Her preprocedural electrocardiograms showed a sinus rhythm without delta wave and a wide-complex short RP tachycardia with a rate of 150 bpm during palpitation. During conventional electrophysiologic study earliest local activation times during the tachycardia were obtained from the right parahisian region (Figure 1). A few second of initial radiofrequency ablation attempts using standard 4-mm tip radiofrequency ablation (RFA) catheter to this region resulted in cessation of the tachycardia and reversible ventriculo-atrial block. Then applying cryothermal energy using 4-mm tip cryoablation (CA) catheter (The Freezor® Cardiac CryoAblation Catheter, Minneapolis, USA) at -30 0C, cryomapping, to the initial site resulted in cessation of the tachycardia and reversible ventriculo-atrial block. The RFA catheter was advanced to the non-coronary cusp of the aortic valve which has close proximity to parahisian region [1,2]. During application of radiofrequency energy the tachycardia stopped but significant prolongation in ventriculo-atrial conduction was detected. Lastly, cryothermal energy was applied in the non-coronary cusp. Cryomapping stopped the tachycardia without any ventriculo-atrial or atrio-ventricular block (Figure 2). Therefore, CA at -70 0C was performed with 2 freeze-thaw cycles (Figure 3a and b). No tachycardia was induced with control programmed and burst pacing maneuvers and the patient was asymptomatic at 6-month follow-up.
منابع مشابه
Para-Hisian atrial tachycardia ablation in a patient with congenitally corrected transposition of great vessels
Introduction Atrial tachycardias originating in the para-Hisian area are not exceptional. In order to avoid iatrogenic atrioventricular block, alternative techniques to conventional radiofrequency ablation have been proposed, such as cryoablation and, recently, ablation from aortic cusps. Nevertheless, para-Hisian areas in patients with transposition of great vessels are not always related to a...
متن کاملRadiofrequency Ablation of an Atrial Tachycardia Emanating From the Non-coronary Aortic Cusp Guided by an Electroanatomic Navigation System
We report on an atrial tachycardia (AT), emanating from the non-coronary (NC) aortic cusp, ablated with the aid of an electro-anatomical navigation system. In this setting, the electrocardiographic, electrophysiologic (EP), anatomical, and ablative considerations are discussed.Although NC aortic cusp focal ATs are an uncommon EP finding, their ablation is effective and safe, especially from an ...
متن کاملAdenosine sensitive focal atrial tachycardia originating from the non-coronary aortic cusp.
We report on the characteristics and the ablation procedure of a focal atrial tachycardia originating from the non-coronary aortic cusp. The electrophysiological features of the tachycardia included: (i) incessant pattern; (ii) easy induction and termination by atrial stimulation; (iii) earliest right atrial activation at the para-hisian area; and (iv) termination by adenosine. Left-sided mappi...
متن کاملPreferential conduction during focal atrial tachycardia arising from the noncoronary cusp
Ventricular arrhythmias arising from a single focus within the left ventricular outflow tract and aortic sinuses of Valsalva may exhibit different QRS morphologies owing to preferential conduction to multiple exits. We describe a case of an atrial tachycardia (AT) arising from the noncoronary aortic cusp (NCC) with different P-wave morphologies, presumably on the basis of preferential conduction.
متن کاملCombination of Hansen Robotic system with cryocatheter in a challenging parahisian accessory pathway ablation
A perceived distinctive feature of cryoablation is the stability (cryoadherence) of the catheter tip during cold temperatures at the desired location, even during tachycardia. We report the case report of a young patient with a parahisian accessory pathway where stability of the ablation catheter was not achieved despite using the cryocatheter with a steerable sheath. Ultimately, stability at t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014