LipoWise: A New Generation of Skinfold Calipers
نویسندگان
چکیده
The skinfold caliper is a non-invasive anthropometric technique regularly used to assess the nutritional status of clinical and non-clinical individual samples for evaluation of body composition percentage. A skinfold caliper allows obtaining important anthropometrical data using a simple and portable tool, with a non-invasive and cost-effective procedure. Using regression equations, the skinfolds thickness measurement allows estimating the individual body fat. However, this approach has some limitations and no evolution has been registered on the skinfold calipers recognized in the literature and used for health, sports and nutritional evaluations. Moreover, studies on the skinfolds compressibility pattern have not been explored because the available skinfolds calipers do not have not this feature which needs to be complemented by data storage tools, namely for large scale studies. Efforts for developing new algorithms, for example, if based in dynamic tissue response are also limited by the traditional skinfold calipers. The integrated LipoTool system intends to contribute to those goals due to its novel characteristics. The LipoTool features are briefly described. The paper highlights the innovative capacities of LipoTool, and explores preliminary studies of the tissue compressibility pattern in order to open new methodology for assessing other parameters rather than the skinfold evaluation based in the use of a high diversity of regression equations to estimate body fat percentage. Different prototypes have been used by people in the health and nutrition areas and, the feedback has been very positive as a powerful tool for assessing and tracking, training and study. Now, the next step is to carry on research in order to develop new models and different application domains. In this work a very exploratory attempt is presented. The LipoTool will be soon in the market and it has been registered as LipoWise. Copyright © 2015 IFSA Publishing, S. L.
منابع مشابه
Comparison of Body Composition Measurements Using a New Caliper, Two Established Calipers, Hydrostatic Weighing, and BodPod
PURPOSES (1) To compare the Lafayette Instruments (LI) skinfold caliper to the Lange (L) and Harpenden (H) calipers using a diverse subject population. (2) To determine the validity of the LI caliper in a subset of subjects by comparing body compositions from skinfold thicknesses to those measured by hydrostatic weighing (HW) and air displacement plethysmography (ADP). (3) To compare measuremen...
متن کاملMeasurement of triceps skinfold thickness. An investigation of sources of variation.
A measurement of the thickness of subcutaneous skinfolds has been widely used as an index of body fat. Edwards et al. (1955) investigated the design and accuracy of skinfold calipers and made a number of recommendations for their construction which were incorporated in the Harpenden skinfold calipers. They found that the precision of the Harpenden skinfold calipers was adequate and that the dif...
متن کاملAssessment of truncal edema following breast cancer treatment using modified Harpenden skinfold calipers.
After initial treatment for breast cancer, lymphedema often affects the trunk as well as the arm. Evaluation of truncal swelling by the clinical "pinch test" of the posterior axillary fold is unreliable. Our aim was to develop an objective measurement, using modified Harpenden skinfold calipers. Standard Harpenden skinfold calipers exert a pressure of 12.6 g.mm-2, which rapidly squeezes edema f...
متن کاملMeasurement of fat thickness in man: a comparison of ultrasound, Harpenden calipers and electrical conductivity.
Indirect estimation of total body fat has been employed increasingly in recent years in an attempt to assess various aspects of body composition. In the most widely used method skinfold thickness is estimated by means of Harpenden calipers (Edwards, Hammond, Healey, Tanner & Whitehouse, 1955; Fletcher, 1962); these require a certain amount of practice in use. Since the instrument measures a ski...
متن کاملRelationship between selected anthropometric variables and performance of volleyball players
The present investigation finds the relationship between selected Anthropometric variables and performance of university level Volleyball Players. For the purpose of the study, thirty (N=30) volleyball players were selected as subjects from the North Zone Inter-University Volleyball Tournament. The selected Anthropometric measurements were taken with the help of vernier calipers and lange’s ski...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015