Reproducibility of baroreflex sensitivity measured by a neck suction method.

نویسندگان

  • J Bene
  • M A Horan
  • J E Clague
چکیده

Lord et al. [1] report wide intra-subject variability of different non-invasive measures of baroreflex sensitivity (BRS) and caution against over-interpretation of minor differences. The authors do not discuss an alternative non-invasive measure of BRS, i.e. the neck suction technique [2–4]. As a preliminary investigation prior to a study of the recovery of cardiovascular reflexes following injury, we have assessed the within-day and between-day variability of the baroreflex measured using the neck suction technique. Healthy male subjects (n ̄ 12, mean age 31.6 years ; range 21–41 years) were studied in the fasting state after micturition. Subjects underwent testing twice, 20 min apart at the same times, on each of 2 days, 7 days apart. Brief applications of negative pressure were applied during held expiration using an R wave-triggered solenoid device. Multiple pressures were applied, each for five consecutive R–R intervals, in random order. The relationship between change in heart period before and after neck suction was determined and plotted against negative pressure. The slope of this relationship, determined by least-squares linear regression, is a measure of baroreflex sensitivity [4]. The median and range of BRS plus the median within-day and between-day variability of the slopes (all four slopes), measured as coefficient of variation, are shown in Table 1. Variability is of a similar magnitude to those of the other techniques reported by Lord et al. [1]. The application of positive as well as negative pressure offers the possibility of examining the full range of response of

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Counteraction of aortic baroreflex to carotid sinus baroreflex in a neck suction model.

Although neck suction has been widely used in the evaluation of carotid sinus baroreflex function in humans, counteraction of the aortic baroreflex tends to complicate any interpretation of observed arterial pressure (AP) response. To determine whether a simple linear model can account for the AP response during neck suction, we developed an animal model of the neck suction procedure in which c...

متن کامل

PATHOPHYSIOLOGY AND NATURAL HISTORY HYPERTENSION Arterial baroreflex sensitivity, plasma catecholamines,

Arterial baroreflex sensitivity, plasma norepinephrine (NE) and epinephrine (E), and pressor and depressor responses were assessed in 25 patients with essential hypertension and 29 normotensive control subjects. Sensitivity of the cardiac limb of the baroreflex was determined by blood pressure and interbeat interval responses associated with the Valsalva maneuver, externally applied neck suctio...

متن کامل

Effects of changes in central blood volume on carotid-vasomotor baroreflex sensitivity at rest and during exercise.

The purpose of this investigation was to examine whether the effect of changes in central blood volume on carotid-vasomotor baroreflex sensitivity at rest was the same during exercise. Eight men (means +/- SE: age 26 +/- 1 yr; height 180 +/- 3 cm; weight 86 +/- 6 kg) participated in the present study. Sixteen Torr of lower body negative pressure (LBNP) were applied to decrease central venous pr...

متن کامل

Carotid baroreflex regulation of sympathetic nerve activity during dynamic exercise in humans.

We sought to determine whether carotid baroreflex (CBR) control of muscle sympathetic nerve activity (MSNA) was altered during dynamic exercise. In five men and three women, 23.8 +/- 0.7 (SE) yr of age, CBR function was evaluated at rest and during 20 min of arm cycling at 50% peak O(2) uptake using 5-s periods of neck pressure and neck suction. From rest to steady-state arm cycling, mean arter...

متن کامل

Spontaneous fluctuation indices of the cardiovagal baroreflex accurately measure the baroreflex sensitivity at the operating point during upright tilt.

Spontaneous fluctuation indices of cardiovagal baroreflex have been suggested to be inaccurate measures of baroreflex function during orthostatic stress compared with alternate open-loop methods (e.g. neck pressure/suction, modified Oxford method). We therefore tested the hypothesis that spontaneous fluctuation measurements accurately reflect local baroreflex gain (slope) at the operating point...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical science

دوره 96 4  شماره 

صفحات  -

تاریخ انتشار 1999