Advances in drug eluting stents – focus on the Endeavor® zotarolimus stent

نویسندگان

  • Jonathan Bridges
  • Donald Cutlip
چکیده

Coronary artery disease remains one of the leading causes of death in the United States. Over the last 30 years, the development of coronary artery angioplasty and stenting has drastically reduced mortality during acute coronary syndromes while also reducing symptoms of chronic coronary artery disease. Unfortunately, the placement of stents in a coronary artery can be complicated by in-stent thrombosis or restenosis. In 2003-2004, a new generation of stents was introduced to the market with the goal of reducing the rate of restenosis. These stents, called drug eluting stents (DES), are coated with a pharmacological agent designed to reduce the neointimal hyperplasia associated with restenosis. Within a year, approximately 80% of all percutaneous coronary interventions performed within the US involved placement of a DES. In 2006, a controversy arose about the possibility of a statistically significant increased risk of acute stent thrombosis associated with DES especially when used for an "off label" indication. This risk was attributed to delayed endothelization. This controversy has led to a reduction in the use of DES along with longer use of dual platelet inhibition with aspirin and clopidogrel. Recently Medtronic introduced a new DES to the market called the Endeavor(®) stent - a zotarolimus eluting stent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.

OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...

متن کامل

Zotarolimus - eluting versus sirolimus - eluting coronary stent implantation review

The safety and efficacy of coronary stents, utilized for treatment of ischemic heart disease, have been evaluated extensively. In comparison with bare-metal stents, first-generation drug-eluting stents more than halved the need for target lesion revascularization, but long-term safety has been questioned, as the first-generation drug-eluting stents seem to be associated with a small, but increa...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009