Progress of Srf Gun Development and Operation at the Elbe Accelerator

نویسندگان

  • J. Teichert
  • A. Arnold
  • P. Murcek
  • R. Xiang
  • P. Lu
  • H. Vennekate
  • T. Kamps
  • J. Rudolph
چکیده

Superconducting RF photo guns are suitable candidates for electron injectors in future free-electron lasers and energy recovery linacs. For the radiation source ELBE an SRF gun was build and put into operation. During longterm tests, the operation of normal-conducting photocathodes in the superconducting cavity has been successfully demonstrated. At moderate average currents of some hundreds of μA the Cs2Te photocathodes possess long lifetime. The acceleration gradient is the key parameters for emittance and the maximum achievable bunch charge of the gun. Therefore two new cavities with higher performance were developed, built and treated. The final tests of these cavities are ongoing. An upgraded cryomodule with an integrated superconducting solenoid was built.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fel Operation with the Superconducting Rf Photo Gun at Elbe

The superconducting RF photoinjector (SRF gun) operating with a 31⁄2-cell niobium cavity and Cs2Te photocathodes is installed at the ELBE radiation center. Since 2012 a new UV driver laser system developed by MBI has been installed for the SRF gun. It delivers CW or burst mode pulses with 13 MHz repetition rate or with reduced rates of 500, 200, and 100 kHz at an average UV laser power of about...

متن کامل

Status of the Superconducting Rf Photo-injector Development*

A status report of the superconducting RF photo electron injector development at Forschungszentrum DresdenRossendorf (FZD) is given. The SRF gun project is a collaboration of BESSY, DESY, MBI and FZD and aims at the installation of a high average current CW photo injector at the ELBE superconducting electron linac. Main design parameters of the SRF gun are an electron energy of 9.5 MeV, a maxim...

متن کامل

Dark Current in Superconducting Rf Photoinjectors – Measurements and Mitigation

Unwanted beam can cause beam losses and may produce acute or chronic damages of the accelerator. Furthermore it can considerably disturb experiments or increase its back-ground. The operation of the superconducting RF photo gun at the ELBE accelerator has delivered the first experimental information on that topic for this gun type. It was found, that dark current is an important issue, similar ...

متن کامل

بررسی تابش کانالی از ‌بلور‌های الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE

The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...

متن کامل

OPTICS DEVELOPMENT AND TRAJECTORY TUNING OF bERLinPro AT LOW ENERGIES*

The Berlin Energy Recovery Linac project has taken shape during the past year. The magnets have been set up in the newly constructed subterraneous hall; first electrons are expected in the SRF-gun test laboratory in June 2017. Starting in February 2018 the complete gun module will be transferred to the accelerator hall for the commissioning of bERLinPro. For the first months, operation is plann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -