Sudden Cardiac Arrest and Death Associated with Application of Shocks from a TASER Electronic Control Device

نویسنده

  • Douglas P. Zipes
چکیده

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, automated external defibrillator information, ECG strips, depositions, and autopsy results were analyzed. First recorded rhythms were ventricular tachycardia/fibrillation in 6 case and asystole (after 30 minutes of nonresponsiveness) in 1 case. An external defibrillator reported a shockable rhythm in 1 case, but no recording was made. This report offers evidence of the mechanism by which an ECD can produce transthoracic stimulation resulting in cardiac electric capture and ventricular arrhythmias leading to cardiac arrest. Conclusions—ECD stimulation can cause cardiac electric capture and provoke cardiac arrest resulting from ventricular tachycardia/ventricular fibrillation. After prolonged ventricular tachycardia/ventricular fibrillation without resuscitation, asystole develops. (Circulation. 2012;125:00-00.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter by Vilke et al regarding article, "sudden cardiac arrest and death following application of shocks from a TASER electronic control device".

BACKGROUND The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. METHODS AND RESULTS Eight cases of TASER X26 ECD-induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, ...

متن کامل

Arrhythmia/Electrophysiology Sudden Cardiac Arrest and Death Following Application of Shocks From a TASER Electronic Control Device

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, au...

متن کامل

Sudden Cardiac Arrest and Death Following Application of Shocks From a TASER Electronic Control Device

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, au...

متن کامل

Can the direct cardiac effects of the electric pulses generated by the TASER X26 cause immediate or delayed sudden cardiac arrest in normal adults?

There is only a small amount of experimental data about whether the TASER X26, a nonlethal weapon that delivers a series of brief electrical pulses to cause involuntary muscular contraction to temporarily incapacitate an individual, can initiate ventricular fibrillation to cause sudden cardiac arrest either immediately or sometime after its use. Therefore, this paper uses the fundamental law of...