Centrifugal analyzer determination of ascorbate in serum or urine with Fe3+/Ferrozine.

نویسندگان

  • W C Butts
  • H J Mulvihill
چکیده

Measurement of serum ascorbate may be useful in long-term population studies because of the possible influence of ascorbate on numerous physiological factors. We describe an automated method for determining ascorbate in serum and urine by using the reduction of ferric iron by ascorbate and the formation of a color between the resulting ferrous iron and Ferrozine [3-(2-pyridyl)-5,6-bis(4-phenylsulfonic acid)-1,2,4-triazine]. A centrifugal analyzer is used to rapidly and simultaneously measure ascorbate in the samples and standards and minimize interference from slower reacting substances in the sample. The method is highly precise and specific. Data are also presented on the stability of ascorbate in serum, urine, and aqueous solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iron speciation at physiological pH in media containing ascorbate and oxygen.

The stability of iron ascorbate solutions was investigated, under both anaerobic and aerobic conditions, with the Fe2+ and Fe3+ indicators, respectively ferrozine and mimosine, at different pH values. The species present under the differing conditions were investigated by electron paramagnetic resonance (EPR) and Mössbauer spectroscopy and by gel-filtration chromatography. At physiological pH (...

متن کامل

An enzymatic method for oxalate automated with the Cobas Fara centrifugal analyzer.

Measurement of oxalate in urine has been automated for use with the Cobas Fara centrifugal analyzer. No sample pretreatment other than (a critical) pH adjustment is required. Between-run CVs were less than 4%. Results were linearly related to oxalate concentration to 1000 mumol/L. Ascorbic acid ingestion, up to 5 g of ascorbate daily, caused no demonstrable interference with the assay. This pra...

متن کامل

Automated enzymic determination of ethanol in blood, serum, and urine with a miniature centrifugal analyzer.

We describe an automated spectrophotometric reaction-rate method for determination of ethanol in serum and urine with a miniature centrifugal analyzer. The theanol is selectively oxidized in the presence of alcochol dehydrogenase and NAD+ to form NADH, which is measured by the rate of change of its absorbance. Reaction rates are determined automatically, and unknown concentrations are calculate...

متن کامل

Evaluation of the Beckman creatinine analyzer.

We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference from bilirubin, protein, lipemia, uric acid, and hemolysis is negligible, but...

متن کامل

Rapid enzymatic determination of amylase in serum and urine using a centrifugal analyzer.

A convenient, totally enzymatic procedure for amylase assay using a centrifugal analyzer is described. The reaction scheme is examined using both starch and maltotetroase as substrates. Data for the reaction kinetics, linearity and sensitivity are presented. The proposed method exhibits linear reaction kinetics between three and five minutes after the initiation of the reaction and is linear to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 21 10  شماره 

صفحات  -

تاریخ انتشار 1975