Evaluation of calling algorithms for array-CGH
نویسندگان
چکیده
Copy number variation (CNV) detection has become an integral part many of genetic studies and new technologies promise to revolutionize our ability to detect and link them to disease. However, recent studies highlight discrepancies in the genome wide CNV profile when measured by different technologies and even by the same technology. Furthermore, the change point algorithms used to call CNVs can have substantial disagreement on the same data set. We focus this article on comparative genomic hybridization (CGH) arrays because this platform lends itself well to accurate statistical modeling. We describe some newer methodological developments in local statistics that are well suited for CNV detection and calling on CGH arrays. Then we use both simulation studies and public data to compare these new local methods with the global methods that currently dominate literature. These results offer suggestions for choosing a particular method and provide insight to the lack of reproducibility that has been seen in the field so far.
منابع مشابه
FACADE: a fast and sensitive algorithm for the segmentation and calling of high resolution array CGH data
The availability of high resolution array comparative genomic hybridization (CGH) platforms has led to increasing complexities in data analysis. Specifically, defining contiguous regions of alterations or segmentation can be computationally intensive and popular algorithms can take hours to days for the processing of arrays comprised of hundreds of thousands to millions of elements. Additionall...
متن کاملCGHcall: calling aberrations for array CGH tumor profiles
UNLABELLED CGHcall achieves high calling accuracy for array CGH data by effective use of breakpoint information from segmentation and by inclusion of several biological concepts that are ignored by existing algorithms. The algorithm is validated for simulated and verified real array CGH data. By incorporating more than three classes, CGHcall improves detection of single copy gains and amplifica...
متن کاملP-112: PGS-Array-CGH Technique: New Technical Approach to Promotion ART Outcome
Background Chromosomal abnormalities are common in embryos from assisted reproductive technology, ranging from 60% abnormal embryos in women
متن کاملP-243: Prenatal Diagnosis Using Array CGH: Case Presentation
Background: Karyotype analysis has been the standard and reliable procedure for prenatal cytogenetic diagnosis since the 1970s. However, the major limitation remains requirement for cell culture, resulting in a delay of as much as 14 days to get the test results.CGH array technology has proven to be useful in detecting causative genomic imbalances or genetic mutations in as many as 15% of child...
متن کاملI-45: FISH and Array CGH for PGD of Cancer
We developed several FISH approaches to enable preimplantation genetic diagnosis of cancer predisposition syndromes. An overview of the applications and the results of those PGDs will be provided. In addition we developed several novel tools to genome wide screen for CNVs and SNPs in single cells. Those technologies are now being applied for polar body, blastomere and blastocyst screening for c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2013