A study of the haptic bearing angles in eyes with the Optiflex anterior chamber implant.
نویسنده
چکیده
Gonioscopy and goniophotography were performed on 137 eyes with the Optiflex angle supported implant. At the time of gonioscopy the lenses had been in situ for a median of 20 months, with a range of 3-38 months. In 75.9% of cases one or both haptics were positioned posterior to the scleral spur with some degree of iris push. Iris tuck was seen in 29.2% of cases. Three different types of fibrous tissue formations were seen in the angles. The first two types (sleeving and iris haptic adhesions) occurred in the majority of cases and were haptic related. The third type was in the form of true peripheral anterior synechiae and occurred in 17.5% of cases. In cases with haptic related adhesions only, the angle remained open. Secondary glaucoma developed in 12 cases (8.7%). Ten cases had open angles. In the remaining two cases peripheral anterior synechiae were present in more than two-thirds of the angle, which was considered to be closed. Total burial of one of the haptics occurred in 25.5% of cases. A prominent iris vessel was observed near one of the haptics in nine cases. The thin looped haptics appear to stimulate fibrous tissue formation in the majority of cases. The haptic related adhesions add to the stability of the implant. It would make dislocation of the lens unlikely, even under severe trauma to the eye. However, once formed it would make removing the implant virtually impossible without severing the haptics. With time and with burial, the haptics seem to move away from the direction of the cornea. Total insulation of the haptic from the peripheral cornea is achieved with the occurrence of total burial.
منابع مشابه
نتایج درازمدت نصب اسکلرال لنزهای داخل چشمی جابجا شده به روش خارج کردن هاپتیک از برش کوچک قرنیه
Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...
متن کاملThe Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملScleral fixation of dislocated posterior chamber intraocular lenses: Temporary haptic externalization through a clear corneal incision.
PURPOSE To report the results of managing dislocated posterior chamber intraocular lenses (PC IOLs) by externalizing the haptics through a clear corneal incision. SETTING The Retina Center at Pali Momi, Aiea, Hawaii, USA. METHODS This retrospective consecutive series comprised cases in which a dislocated PC IOL was managed with pars plana vitrectomy. With this method, the dislocated PC IOL ...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملScanning electron microscopic characteristics of phakic intraocular lenses.
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 71 4 شماره
صفحات -
تاریخ انتشار 1987