How accurate is multiparametric MR imaging in evaluation of prostate cancer volume?

نویسندگان

  • Flavie Bratan
  • Christelle Melodelima
  • Rémi Souchon
  • Au Hoang Dinh
  • Florence Mège-Lechevallier
  • Sébastien Crouzet
  • Marc Colombel
  • Albert Gelet
  • Olivier Rouvière
چکیده

PURPOSE To assess the factors influencing multiparametric (MP) magnetic resonance (MR) imaging accuracy in estimating prostate cancer histologic volume (Vh). MATERIALS AND METHODS A prospective database of 202 patients who underwent MP MR imaging before radical prostatectomy was retrospectively used. Institutional review board approval and informed consent were obtained. Two independent radiologists delineated areas suspicious for cancer on images (T2-weighted, diffusion-weighted, dynamic contrast material-enhanced [DCE] pulse sequences) and scored their degree of suspicion of malignancy by using a five-level Likert score. One pathologist delineated cancers on whole-mount prostatectomy sections and calculated their volume by using digitized planimetry. Volumes of MR true-positive lesions were measured on T2-weighted images (VT2), on ADC maps (VADC), and on DCE images [VDCE]). VT2, VADC, VDCE and the greatest volume determined on images from any of the individual MR pulse sequences (Vmax) were compared with Vh (Bland-Altman analysis). Factors influencing MP MR imaging accuracy, or A, calculated as A = Vmax/Vh, were evaluated using generalized linear mixed models. RESULTS For both readers, Vh was significantly underestimated with VT2 (P < .0001, both), VADC (P < .0001, both), and VDCE (P = .02 and P = .003, readers 1 and 2, respectively), but not with Vmax (P = .13 and P = .21, readers 1 and 2, respectively). Mean, 25th percentile, and 75th percentile, respectively, for Vmax accuracy were 0.92, 0.54, and 1.85 for reader 1 and 0.95, 0.57, and 1.77 for reader 2. At generalized linear mixed (multivariate) analysis, tumor Likert score (P < .0001), Gleason score (P = .009), and Vh (P < .0001) significantly influenced Vmax accuracy (both readers). This accuracy was good in tumors with a Gleason score of 7 or higher or a Likert score of 5, with a tendency toward underestimation of Vh; accuracy was poor in small (<0.5 cc) or low-grade (Gleason score ≤6) tumors, with a tendency toward overestimation of Vh. CONCLUSION Vh can be estimated by using Vmax in aggressive tumors or in tumors with high Likert scores.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prostate cancer: multiparametric MR imaging for detection, localization, and staging.

This review presents the current state of the art regarding multiparametric magnetic resonance (MR) imaging of prostate cancer. Technical requirements and clinical indications for the use of multiparametric MR imaging in detection, localization, characterization, staging, biopsy guidance, and active surveillance of prostate cancer are discussed. Although reported accuracies of the separate and ...

متن کامل

Multiparametric Magnetic Resonance Imaging of Recurrent Prostate Cancer.

Multiparametric magnetic resonance (MR) imaging of the prostate combines both morphological and functional MR techniques by utilizing small field of view T1-weighted, T2-weighted, diffusion-weighted imaging, dynamic contrast-enhanced imaging, and MR spectroscopy to accurately detect, localize, and stage primary and recurrent prostate cancer. Localizing the site of recurrence in patients with ri...

متن کامل

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Dosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer

Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated....

متن کامل

MRI in Prostate Cancer

Imaging studies play an important role in detection and management of prostate cancer and MRI especially with the use of endorectal coil because of high contrast resolution is recognized as the best imaging modality in evaluation of prostate cancer. Multiparametric MR study including T1 and T2 weighted images, diffusion weighted images, dynamic contrast study and MR spectroscopy is useful for d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 275 1  شماره 

صفحات  -

تاریخ انتشار 2015