Test of response linearity for magnetic force microscopy data
نویسندگان
چکیده
The utility of vertical propagation by the Green’s function to test response linearity has been explored for magnetic force microscopy ~MFM! data from current-carrying wires, by comparing the measured signal at various tip heights to the corresponding propagated MFM signals. Application of a one-dimensional Green’s function was found to be sufficient to predict signal height variation for sample regions of high to moderate field symmetry. For regions of high field asymmetry, the two-dimensional Green’s function was required to obtain good prediction of the height variation. Agreement between the measured and propagated signals was generally within 5%, except at the tails where the signal is not well behaved. The quality of agreement deteriorates gradually with the size of the height propagation. The good agreement spanning a decade of tip and sample separation suggests that the MFM signal is not significantly affected by nonlinearities and can thus be interpreted in terms of classical electromagnetic relations governing current flow. © 2002 American Institute of Physics. @DOI: 10.1063/1.1489701#
منابع مشابه
Magnetic force microscopy using fabricated cobalt-coated carbon nanotubes probes
Magnetic force microscope ( MFM ) is a powerful technique for mapping the magnetic force gradient above the sample surface. Herein, single-wall carbon nanotubes (SWCNT) were used to fabricate MFM probe by dielectrophoresis method which is a reproducible and cost-effective technique. The effect of induced voltage on the deposition manner of carbon nanotubes (CNT) on the atomic force microscope (...
متن کاملFe3O4/CNT Magnetic Nanocomposites as Adsorbents to Remove Organophosphorus Pesticides from Environmental Water
In this study, a method for extraction and preconcentration of trace amounts of organophosphorus pesticides (OPPs) in environmental water using magnetic solid phase extraction (magnetic-SPE) followed by high performance liquid chromatography (HPLC) with UV detection was developed. The magnetic carbon nanotube adsorbents (Fe3O4/CNT) were synthesized by grafting carbo...
متن کاملSensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...
متن کاملOptimization of the FeCo nanowire fabrication embedded in anodic aluminum oxide template by response surface methodology
Anodic aluminum oxide (AAO) fabricated by two step anodization technique, is used as a template to synthesize FeCo nanowire arrays by AC electrodeposition technique. Response surface methodology (RSM) is applied to design the experiments, fit an empirical model and optimize the conditions to achieve the best magnetic properties. The magnetic properties, pore dimensions, composition and structur...
متن کاملEffective Parameters in Contact Mechanic for Micro/nano Particle Manipulation Based on Atomic Force Microscopy
The effect of geometry and material of the Micro/Nano particle on contact mechanic for manipulation was studied in this work based on atomic force microscopy. Hertz contact model simulation for EpH biological micro particle with spherical, cylindrical, and circular crowned roller shape was used to investigate the effect of geometry on contact simulation process in manipulation. Then, to val...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002