Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron microscope in endodontic surgery

نویسندگان

  • Ramón Rodríguez-Martos
  • Daniel Torres-Lagares
  • Lizett Castellanos-Cosano
  • María A. Serrera-Figallo
  • Juan J. Segura-Egea
  • Jose L. Gutierrez-Perez
چکیده

OBJECTIVE The objective of our study is to analyse (with the help of scanning electron microscopes) the quality of the dental root surface and the appearance of dental cracks after performing apical preparations using two different types of ultrasonic tips. STUDY DESIGN We used 32 single-rooted teeth that underwent a root canal and apical resection. Afterwards, the teeth were divided into 4 groups of 8 teeth each, with preparations of the apical cavities in the following manner: Group 1: stainless steel ultrasonic tip at 33 KHz. Group 2: stainless steel ultrasonic tip at 30 KHz. Group 3: diamond ultrasonic tip at 30 KHz. Group 4: diamond ultrasonic tip at 33 KHz. The quality of the root surface and the presence of cracks were evaluated by one single observer using a scanning electron microscope. RESULTS All of the teeth in our study had cracks after the apical preparations. The mean number of cracks per tooth ranged between 6. ± 1.9 (group 1) and 3.5 ± 2.4 (group 4), with a significantly higher number found in the groups that used stainless steel tips (P=.03). The types of cracks produced involved: 8 complete cracks (4.5%), 167 incomplete cracks (94.4%), and 2 intradentinal cracks (1.1%), with no significant differences observed between the different frequencies used for each group. CONCLUSIONS Stainless steel ultrasonic tips provoked a larger number of cracks than diamond tips. The frequency of vibration used did not have any effect on the number of cracks found.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Confocal microscopy: A valid approach to evaluate the three-dimensional characteristics of root-end cavities

OBJECTIVE To analyze, using confocal microscope, the three-dimensional characteristics of the root-end cavity preparations completed in root apices of extracted teeth determining their area, perimeter, circularity and cavo-surface angle. STUDY DESIGN Thirty-two single-rooted extracted teeth underwent endodontic treatment and apical resection. Root-end cavities were prepared according to 4 pro...

متن کامل

Evaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique

BACKGROUND Although many studies have compared the properties of ultrasonic scaling instruments, it remains controversial as to which is most suitable for implant scaling. This study evaluated the safety and efficiency of novel metallic ultrasonic scaler tips made by the powder injection molding (PIM) technique on titanium surfaces. METHODS Mechanical instrumentation was carried out using fou...

متن کامل

Effect of sputter-coating on cracking of root-end surfaces after ultrasonic retrograde preparation--a SEM study of resected root apices and their respective impressions.

The aim of this study was to evaluate in vitro the effect of sputter-coating for SEM analysis on the formation of cracks on root-end surfaces after retrograde cavity preparation with ultrasonic tips. Root-end cavities were prepared with either Satelec S12/90 degrees D diamond-coated or S12/90 degrees non-coated stainless steel retrotips. Impressions were taken before and after retrograde cavity...

متن کامل

A comparative study of the cleaning effect of various ultrasonic cleaners on ‎new, unused endodontic instruments

BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...

متن کامل

Corrosion Behaviour of Nickel Coated AISI 316 Stainless Steel as a Function of Annealing Temperature

AISI 316 stainless steels were coated with 250 nm Ni film by electron beam deposition and post-annealed at different temperatures with a nitrogen flow of 600 cm3min-1 nitrogen. The prepared samples were corrosion tested in 1.0 M sulphuric acid solution using potentiodynamic technique. Crystallographic and morphological structure of the samples were analyzedanalysed by X-ray diffraction (XRD) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2012