Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

نویسندگان

  • Jessica S. Coogan
  • W. Loren Francis
  • Travis D. Eliason
  • Todd L. Bredbenner
  • Brian D. Stemper
  • Narayan Yoganandan
  • Frank A. Pintar
  • Daniel P. Nicolella
چکیده

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in Finite Element Applications in Artificial Lumbar Disc Replacement

As a new choice for the treatment of degenerative lumbar disease, artificial lumbar disc replacement has been widely used in clinical surgery. The finite element is a very effective method to predict and simulate the surgery effect. The purpose of this paper is to review the applications of finite element in artificial lumbar disc replacement, such as design of artificial lumbar disc prosthesis...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Design of an Elastic Arthroplastic Disc Optimized under Different Loads

Introduction: Due to limitations of current treatments for degenerative disc disease, arthroplastic methods to repair the diseased disc have been proposed. The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements following interbody fusion procedures. Because the success of artificial disc replacement depends on ...

متن کامل

The effect of nucleus implant parameters on the compressive mechanics of the lumbar intervertebral disc: a finite element study.

A simplified finite element model of the human lumbar intervertebral disc was utilized for understanding nucleus pulposus implant mechanics. The model was used to assess the effect of nucleus implant parameter variations on the resulting compressive biomechanics of the lumbar anterior column unit. The effects of nucleus implant material (modulus and Poisson's ratio) and geometrical (height and ...

متن کامل

Study on Lumbar Vertebrae Biomechanical Characteristics for Speed Skating Athlete Based on Finite Element Method

Objective: To establish the three-dimensional finite element model of lumbar motion segment (L4-L5) that considers material property and geometrical behave, to investigate mechanical characteristics of lumbar spinal motion segment for application of prevention and reduction of lumbar trauma for the speed skating athletes. Methods: three-dimensional finite element model (FEM) of the human lumbar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016