Optic disc measurement with the Zeiss four mirror contact lens.

نویسندگان

  • A F Spencer
  • S A Vernon
چکیده

A knowledge of the optic disc size may be of value when assessing the glaucoma suspect. The vertical diameter of the optic disc was measured using a Zeiss four mirror gonioscope and a 900 Haag-Streit slit-lamp in one eye of 39 patients, 32 with refractive errors within 3 dioptres of emmetropia. The disc was measured by projecting a slit beam of known height onto the image of the disc. A magnification factor for the contact lens was calculated from first principles and disc height recalculated. These measurements were compared with those obtained by photographic methods using the corrections suggested by Bengtsson and Krakau. In the analysis on the 32 eyes within 3 dioptres of emmetropia the best correlation with clinical measurements was obtained with correction 3 using spectacle refraction and keratometry (r = 0.8614). The contact lens measurement was within plus or minus 0.1 mm of the photographic measurement in 67% of cases and plus or minus 0.2 mm in all cases. This simple method is advocated for the routine assessment of optic disc size.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential Diagnosis of the Big Cup

Evaluation of the optic nerve head includes both observational and functional studies. Direct study of the optic disc often employs the hand held ophthalmoscope with the accessory use of a green light to allow improved visualization of the nerve fiber layer. Comprehensive analysis of the optic disc is better achieved using a stereoscopic view, which can be obtained directly through the use of v...

متن کامل

Use of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog

This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...

متن کامل

Optic disc imaging in conscious rats and mice.

PURPOSE To determine whether useful images of the optic discs of conscious rats and mice can be obtained by using a photo slit lamp and a modified Goldmann-type fundus contact lens. METHODS Testing was performed with a photo slit lamp equipped with two 2x teleconverters and a digital camera through a Goldmann-type fundus contact lens that was fabricated for the rodent eye. RESULTS Images of...

متن کامل

Magnification characteristic of a +90-diopter double-aspheric fundus examination lens.

PURPOSE To investigate the magnification characteristic of the +90-D double-aspheric fundus examination lens for biomicroscopic measurement of the optic disc. METHODS A calibrated Gullstrand-type model eye adjusted for axial ametropia between -12.5 and +12.6 D was used to measure the change in magnification of the system with refractive error and variation in fundus lens position. A correctio...

متن کامل

Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.

PURPOSE To evaluate the influence of disease severity and optic disc size on the diagnostic accuracy of three imaging technologies for structural assessment in glaucoma: confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography. METHODS One hundred five patients with glaucoma and 61 normal subjects were recruited from the Diagnostic Innovations in Gl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 78 10  شماره 

صفحات  -

تاریخ انتشار 1994