EQCM analysis of titanium corrosion in peroxide- or fluoride-containing solutions.

نویسندگان

  • Masayuki Hattori
  • Yutaka Oda
چکیده

Although offering superior resistance to corrosion, titanium is unable to withstand discoloration with exposure to peroxide or fluoride. The mechanism of this discoloration, however, remains to be clarified. The purpose of this study was to investigate the mechanism underlying discoloration of titanium with immersion in peroxide- or fluoride-containing solutions based on electrochemical quartz crystal microbalance (EQCM) analysis. A 9-MHz titanium-deposited quartz crystal was used as for the electrodes. Four test solutions were prepared for immersion of the electrodes: 154 mM (0.9%) NaCl; 150 mM H2O2+154 mM NaCl (pH=4 by addition of lactic acid); 150 mM H2O2+154 mM NaCl (pH=8 by addition of sodium hydroxide solution); and 48 mM (0.2%) NaF+154 mM NaCl (pH=5.0 by addition of lactic acid). A WinEchem electrochemistry software-controlled quartz crystal analyzer (QCA922) and the Potentiostat/Galvanostat (Princeton Applied Research) on Windows XP were used to measure concurrently the resonance frequency and potential of the electrodes. The EQCM data differed among solutions. In the acidulated fluoride-containing solution, the electrode showed lower open circuit potential and a gradual increase in electrode frequency, indicating a loss of mass by titanium dissolution. In the peroxide-containing solution, although open circuit potential showed no marked difference, electrode frequency showed a gentle decrease in acidic solution, indicating a gain in mass by oxidation; but an increase in alkaline solution, indicating a loss of mass by dissolution. These results confirmed that exposure to acidulated fluoride- or alkaline peroxide-containing solutions causes dissolution-induced discoloration, while that to acidulated peroxide-containing solutions resulted in the formation of an oxide film together with discoloration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suppression of fluoride-induced corrosion of titanium by albumin in oral modified environment.

Although fluoride induces corrosion in titanium in an oral environment, the influence of protein on this corrosion remains to be clarified. The objective of this study was to investigate suppression of fluoride-induced corrosion of titanium where albumin was either present in a solution or where albumin was preadsorbed on titanium. Titanium dissolution in titanium specimens and surface characte...

متن کامل

Inhibitory Effect of Propolis against Corrosion Evaluated by Electrochemical Methods of Ti Grade 2 in Artificial Fluoride Saliva

The objective of this work was to demonstrate the effect of fluoride and propolis extract on the corrosion behavior of commercially pur titanium (cp-Ti grade 2) in artificial saliva. The inhibition studies were approved out on cp-Ti as dental implant in Fusayama-Meyer with the propolis extract using potentiodynamic polarization and Electrochemical Impedance Spectroscopy (EIS). Parameters, such ...

متن کامل

Discoloration of titanium alloy in acidic saline solutions with peroxide.

The objective of this study was to compare corrosion behavior in several titanium alloys with immersion in acidulated saline solutions containing hydrogen peroxide. Seven types of titanium alloy were immersed in saline solutions with varying levels of pH and hydrogen peroxide content, and resulting differences in color and release of metallic elements determined in each alloy. Some alloys were ...

متن کامل

Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.

The effects of fluoride concentrations and pH on the corrosion behavior of pure titanium, Ti-6Al-4V, Ti-6Al-7Nb alloys and a new Ti alloy adding palladium, which is expected to promote a repassivation of Ti were examined by anodic polarization and corrosion potential measurements. The amount of dissolved Ti was analyzed by inductively coupled plasma mass spectroscopy. The surface of the specime...

متن کامل

Discoloration and Dissolution of Titanium Peroxide - or Fluoride - containing Solutionsand Titanium Alloys withImmersion in

fluoride-containing solutien. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-O.15Pd, Ti6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were prepared fbr immersion of polished titanium and titanium alloys: one consisting of O,2% NaF + O,9% NaCl (pH 3.8 with lactic acid) and the other of O.1 mol/1 H202 + O.9% NaCl (pH 5.5). Following immersion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Bulletin of Tokyo Dental College

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2013