Accelerated partial breast irradiation in an Asian population: dosimetric findings and preliminary results of a multicatheter interstitial program
نویسندگان
چکیده
INTRODUCTION Accelerated partial breast irradiation (APBI) using the multicatheter method has excellent cosmesis and low rates of long-term toxicity. However, there are few studies looking at the feasibility of this procedure and the outcomes in an Asian population. This study aims to look at outcomes at our hospital. METHODS We identified 121 patients treated with APBI at our center between 2008 and 2014. The median follow-up for our patient group was 30 months (range 3.7-66.5). The prescribed dose per fraction was 3.4 Gy in 10 fractions. In this study population, 71% of the patients were Chinese while 15% (n=19) were of other Asian ethnicity. RESULTS In this study, the median breast volume was 850 cc (range 216-2,108) with 59.5% (n=72) patients with a breast volume of <1,000 cc. The average planning target volume was 134 cc (range 28-324). The number of catheters used ranged from 8 to 25 with an average of 18 catheters used per patient. We achieved an average dose homogeneity index of 0.76 in our patients. The average D90(%) was 105% and the average D90(Gy) was 3.6 Gy per fraction. The median volume receiving 100% of the prescribed dose (V100) was 161.7 cc (range 33.9-330.1), 150% of the prescribed dose (V150) and 200% of the prescribed dose (V200) was 39.4 cc (range 14.6-69.6) and 14.72 cc (range 6.48-22.25), respectively. Our dosimetric outcomes were excellent even in patients with breast volume under 1,000 cc. There were no cases of grade 3 skin toxicity or acute pneumonitis. Two patients had a postoperative infection and two patients had fat necrosis postprocedure. CONCLUSION Multicatheter high dose rate APBI is a safe and feasible procedure that can be carried out with minimal toxicity in Asian patients with breast volumes under 1,000 cc.
منابع مشابه
Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation
PURPOSE Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We aim to compare dosimetric endpoints between the template and non-template approach. MATERIAL AND ...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملHigh-dose-rate interstitial brachytherapy for accelerated partial breast irradiation – trial results of Azerbaijan National Center of Oncology
PURPOSE To describe early results of two cohorts of patients with low and intermediate risk of early breast cancer treated with accelerated partial breast irradiation (APBI) using different schedules of multicatheter brachytherapy. MATERIAL AND METHODS Patients with early stage breast cancer after breast conserving surgery were enrolled for a prospective analysis. The APBI, using multicathete...
متن کاملComparison of accelerated partial breast irradiation via multicatheter interstitial brachytherapy versus whole breast radiation
BACKGROUND Brachytherapy as adjuvant treatment for early-stage breast cancer has become widely available and offers patients an expedited treatment schedule. Given this, many women are electing to undergo brachytherapy in lieu of standard fractionation radiotherapy. We compare outcomes between patients treated with accelerated partial breast irradiation (APBI) via multicatheter interstitial bra...
متن کاملMulti-catheter interstitial brachytherapy for partial breast irradiation: an audit of implant quality based on dosimetric evaluation comparing intra-operative versus post-operative placement
PURPOSE The use of multicatheter interstitial brachytherapy (MIB) for accelerated partial breast irradiation (APBI) in early breast cancer (EBC) patients outside the trial setting has increased. Hence, there is a need to critically evaluate implant quality. Moreover, there is a scarcity of reports using an open cavity technique. We report the dosimetric indices of open and closed cavity MIB tec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -