Information from dynamic length changes improves reliability of static ultrasound fascicle length measurements

نویسندگان

  • Jeroen Aeles
  • Glen A. Lichtwark
  • Sietske Lenchant
  • Liesbeth Vanlommel
  • Tijs Delabastita
  • Benedicte Vanwanseele
چکیده

Purpose Various strategies for improving reliability of fascicle identification on ultrasound images are used in practice, yet these strategies are untested for effectiveness. Studies suggest that the largest part of differences between fascicle lengths on one image are attributed to the error on the initial image. In this study, we compared reliability results between different strategies. Methods Static single-image recordings and image sequence recordings during passive ankle rotations of the medial gastrocnemius were collected. Images were tracked by three different raters. We compared results from uninformed fascicle identification (UFI) and results with information from dynamic length changes, or data-informed tracking (DIT). A second test compared tracking of image sequences of either fascicle shortening (initial-long condition) or fascicle lengthening (initial-short condition). Results Intra-class correlations (ICC) were higher for the DIT compared to the UFI, yet yielded similar standard error of measurement (SEM) values. Between the initial-long and initial-short conditions, similar ICC values, coefficients of multiple determination, mean squared errors, offset-corrected mean squared errors and fascicle length change values were found for the DIT, yet with higher SEM values and greater absolute fascicle length differences between raters on the first image in the initial-long condition and on the final image in the initial-short condition. Conclusions DIT improves reliability of fascicle length measurements, without lower SEM values. Fascicle length on the initial image has no effect on subsequent tracking results. Fascicles on ultrasound images should be identified by a single rater and care should be taken when comparing absolute fascicle lengths between studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review.

Ultrasound imaging is widely used to measure architectural features of human skeletal muscles in vivo. We systematically reviewed studies of the reliability and validity of two-dimensional ultrasound measurement of muscle fascicle lengths or pennation angles in human skeletal muscles. A comprehensive search was conducted in June 2011. Thirty-six reliability studies and six validity studies met ...

متن کامل

UltraTrack: Software for semi-automated tracking of muscle fascicles in sequences of B-mode ultrasound images

BACKGROUND Dynamic measurements of human muscle fascicle length from sequences of B-mode ultrasound images have become increasingly prevalent in biomedical research. Manual digitisation of these images is time consuming and algorithms for automating the process have been developed. Here we present a freely available software implementation of a previously validated algorithm for semi-automated ...

متن کامل

Reliability of Functional Balance Assessment Tests in Children aged 7-10 and its Correlation with Selected Anthropometric Parameters

Introduction: The present study evaluates reliability of functional balance assessment tests in children aged 7-10 and its correlation with selected anthropometric parameters. Methodology: Population of the study includes 80 students aged 7-10 (40 female and 40 male). The Sharpened Romberg Test was used for static balance, while timed up and go test, Tandem walk test, and Y test were used for ...

متن کامل

Automatic tracking of medial gastrocnemius fascicle length during human locomotion.

During human locomotion lower extremity muscle-tendon units undergo cyclic length changes that were previously assumed to be representative of muscle fascicle length changes. Measurements in cats and humans have since revealed that muscle fascicle length changes can be uncoupled from those of the muscle-tendon unit. Ultrasonography is frequently used to estimate fascicle length changes during h...

متن کامل

In vivo assessment of muscle fascicle length by extended field-of-view ultrasonography.

The present study examined the reliability and validity of in vivo vastus lateralis (VL) fascicle length (L(f)) assessment by extended field-of-view ultrasonography (EFOV US). Intraexperimenter and intersession reliability of EFOV US were tested. Further, L(f) measured from EFOV US images were compared to L(f) measured from static US images (6-cm FOV) where out-of-field fascicle portions were t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017