A critical analysis of the degree of conversion of resin-based luting cements

نویسندگان

  • Jaime Dutra NORONHA FILHO
  • Natasha Lamego BRANDÃO
  • Laiza Tatiana POSKUS
  • José Guilherme Antunes GUIMARÃES
  • Eduardo Moreira da SILVA
چکیده

OBJECTIVE This study analyzed the degree of conversion (DC%) of four resin-based cements (All Ceram, Enforce, Rely X ARC and Variolink II) activated by two modes (chemical and dual), and evaluated the decrease of DC% in the dual mode promoted by the interposition of a 2.0-mm-thick IPS Empress 2 disc. MATERIAL AND METHODS In the chemical activation, the resin-based cements were prepared by mixing equal amounts of base and catalyst pastes. In the dual activation, after mixing, the cements were light-activated at 650 mW/cm² for 40 s. In a third group, the cements were light-activated through a 2.0-mm-thick IPS Empress 2 disc. The DC% was evaluated in a FT-IR spectrometer equipped with an attenuated total reflectance crystal (ATR). The data were analyzed by two-way ANOVA and Tukey's HSD test. RESULTS For all resin-based cements, the DC% was significantly higher with dual activation, followed by dual activation through IPS Empress 2, and chemical activation (p<0.05). Irrespective of the activation mode, Rely X presented the highest DC% (p<0.05). Chemically activated Variolink and All Ceram showed the worst results (p<0.05). The DC% decreased significantly when activation was performed through a 2.0-mm-thick IPS Empress 2 disc (p<0.05). CONCLUSION The results of the present study suggest that resin-based cements could present low DC% when the materials are dually activated through 2.0 mm of reinforced ceramic materials with translucency equal to or less than that of IPS-Empress 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the effect of ceramic veneer thickness on degree of conversion in three luting resin cements

compare the effect of different ceramic thicknesses on degree of conversion (DC) of 3 light-cured resin cements. Methods: In this experimental in-vitro study, the degree of conversion of three light-cured resin cements, Variolink Veneer (Ivoclar, Liechtenstein), RelyX Veneer (3M ESPE, USA) and Choice2 (Bisco, USA) were evaluated beneath feldespatic ceramic discs (Vita VMK Master) with a same sh...

متن کامل

پلیمریزاسیون سیمان‌های رزینی دوال کیور کاربردی جهت چسباندن پست‌های فایبری هم‌رنگ دندان

Background and Aim: Insufficient polymerization of resin cements is of considerable clinical importance, because of mechanical deficiencies and biological side effects of uncured resin. Dual cure resin cements are getting popular in luting tooth colored posts and although their curing is claimed to proceed chemically, polymerization efficiency in deep areas of canal is uncertain. The aim of thi...

متن کامل

Nanoindentation tests to assess polymerization of resin-based luting cement.

OBJECTIVE The optimal polymerization of resin-based luting cements plays a critical role in the long-term clinical success of dental prostheses and indirect restorations. This study investigated a mutual action between the conformational changes and mechanical properties of a dimethacrylate resin-based luting cement with and without pre-application of the acidic functional monomer 10-methacrylo...

متن کامل

Correlation between clinical performance and degree of conversion of resin cements: a literature review

Resin-based cements have been frequently employed in clinical practice to lute indirect restorations. However, there are numerous factors that may compromise the clinical performance of those cements. The aim of this literature review is to present and discuss some of the clinical factors that may affect the performance of current resin-based luting systems. Resin cements may have three differe...

متن کامل

Evaluation of Tensile Bond Strength between Dentin and Metallic Copings Using Different Resin Cements

Statement of the Problem: For a successful clinical outcome, luting agents should have a high bond strength. Bond failure is still one of the main reasons of restoration failures. Purpose: The present study was designed to comparatively evaluate the retention of metallic copings using different resin luting cements. Materials and Method: In the present experimental study, 40 intact premolar tee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2010