Determination of aluminium and chromium in slurried baby food samples by electrothermal atomic absorption spectrometry.

نویسندگان

  • P Viñas
  • M Pardo-Martínez
  • M Hernández-Córdoba
چکیده

Electrothermal atomic absorption spectrometry was used to determine aluminium and chromium in different types of baby foods. Samples without previous treatment were introduced into the atomizer as suspensions, which were prepared in a medium containing 0.1% (w/v) Triton X-100 (for chromium) or 10% (v/v) ethanol (for aluminium), 5% (v/v) concentrated hydrogen peroxide, and 0.5% (v/v) concentrated nitric acid. The slurries were homogenized with a potter and introduced directly into the furnace. The presence of nitric acid allowed a substantial amount of analyte to be extracted to the liquid phase. No matrix effect was observed and aqueous standard solutions were used for calibration. The detection limits were 4 and 50 pg for chromium and aluminium, respectively; characteristic masses were 3.8 pg for chromium and 18 pg for aluminium. Reliability of the procedures was checked by statistically comparing the results with those obtained with a previous microwave oven mineralization stage and by analyis of several certified reference materials. Values for the aluminium content ranged between 0.4 and 3.0 microg/g, and for chromium between 0.003 and 0.06 microg/g.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Determination of trace amounts of chromium ions in water and food samples using ligand-less solid phase extraction-based modified nano-boehmite(AlOOH)

Chromium is one of the hazardous pollutants in industrial effluents. In this study, a new nano-boehmite modified with sodium dodecyl sulphate is developed for preconcentration trace amounts of chromium ions as a prior step to its determination by flame atomic absorption spectrometry. We investigated the effect of various parameters on the recovery of the analyte ions, including pH of sample solut...

متن کامل

Determination of Chromium in Biological Material by Electrothermal Atomic Absorption Spectrometry Method

Procedure for determination of chromium in biological materials by Zeeman graphite furnace atomic absorption spectrometry method using a Perkin-Elmer spectrometer equipped with hollow-cathode lamp at 357.9 nm was developed. The samples of animal tissues, food, and feed were digested in muffle furnace at 450oC. The ash was dissolved in 1 N hydrochloric acid and the final solution was diluted in ...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 4  شماره 

صفحات  -

تاریخ انتشار 2001