Efficient computation of articulated-body inertias using successive axial screws

نویسندگان

  • Scott McMillan
  • David E. Orin
چکیده

The articulated-body (AB) algorithm for dynamic simulation of chains of rigid bodies was developed by Featherstone 1]. The most costly step in this algorithm is the computation of the AB inertias at each link which involves a spatial (6 6) congruence transformation. The amount of computation required is closely coupled to the kinematic modeling technique used. This paper examines this computation in detail and presents an eecient step-by-step procedure for its evaluation in a serial chain with revolute and prismatic joints using modiied Denavit-Hartenberg parameters for modeling the kinematics. The result is a very eecient procedure using successive axial screws that reduces the computational requirements of the AB algorithm by about 15% from results obtained by Brandl, Johanni, and Otter 2]. The procedure developed deenes a general approach and can be used to improve the eeciency of spatial congruence transformations of other types of matrices, such as spatial rigid-body inertias (used in the Composite Rigid-Body simulation algorithm 3, 4]).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

متن کامل

Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report

BACKGROUND Use of computer-assisted insertion of pedicle screws has some advantages owing to the reportedly decreased incidence of pedicle breach and clinical events. Registration-based methods based on preoperative computed tomography imaging, 2D fluoroscopy, and 3D fluoroscopy are the most popular, however each has its limitations. O-arm-based navigation, which uses intraoperative acquisition...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Fracture fixation with two locking screws versus three non-locking screws

OBJECTIVES We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone. METHODS Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two...

متن کامل

Efficient Path Planning for Highly Articulated Robots using Adaptive Forward Dynamics

We present an efficient path planning algorithm for highly articulated robots with many degrees of freedom (DoFs). Our approach takes into account physical and geometric constraints and formulates the problem as constrained dynamic simulation. We simulate the motion of the robot using a sub-linear time adaptive forward dynamics algorithm. We also present fast collision detection and response co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE Trans. Robotics and Automation

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1995