Establishing a gold standard for manual cough counting: video versus digital audio recordings
نویسندگان
چکیده
BACKGROUND Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. METHODS We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. RESULTS The median cough frequency was 17.8 (IQR 5.9-28.7) cough sounds per hour in the video recordings and 17.7 (6.0-29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD +/- 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2-4 hours of analysis per recording. CONCLUSION Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment.
منابع مشابه
The automatic recognition and counting of cough
BACKGROUND Cough recordings have been undertaken for many years but the analysis of cough frequency and the temporal relation to trigger factors have proven problematic. Because cough is episodic, data collection over many hours is required, along with real-time aural analysis which is equally time-consuming. A method has been developed for the automatic recognition and counting of coughs in so...
متن کاملData reduction for cough studies using distribution of audio frequency content
UNLABELLED BACKGROUND Recent studies suggest that objectively quantifying coughing in audio recordings offers a novel means to understand coughing and assess treatments. Currently, manual cough counting is the most accurate method for quantifying coughing. However, the demand of manually counting cough records is substantial, demonstrating a need to reduce record lengths prior to counting wh...
متن کاملCough frequency monitors: can they discriminate patient from environmental coughs?
BACKGROUND Objective cough frequency measurements are increasingly applied in clinical research. Technological advances enable automated detection and counting of cough events from sound recordings of many hours' duration. A possible limitation of sound-based cough frequency measurement is the contamination of recordings by environmental coughs (coughs from persons other than the patient). This...
متن کاملEvaluation of a new self-contained, ambulatory, objective cough monitor
OBJECTIVE AND BACKGROUND Objective monitoring of cough may be preferred to subjective reporting of the symptom in clinical and research settings. Therefore, a self-contained, ambulatory cough monitoring system is needed that is non-invasive, usable for children and adults of all ages, inexpensive, and highly accurate with easy to use analysis software. METHODOLOGY After development of a new d...
متن کاملSimultaneous versus video counting of coughs in hypertonic cough challenges
BACKGROUND The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challenges with hypertonic aerosols have been introduced. They often provoke very frequent coughing which...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cough (London, England)
دوره 2 شماره
صفحات -
تاریخ انتشار 2006