Limitations of pulmonary embolism ICD-10 codes in emergency department administrative data: let the buyer beware

نویسندگان

  • Kristin Burles
  • Grant Innes
  • Kevin Senior
  • Eddy Lang
  • Andrew McRae
چکیده

BACKGROUND Administrative data is a useful tool for research and quality improvement; however, validity of research findings based on these data depends on their reliability. Diagnoses assigned by physicians are subsequently converted by nosologists to ICD-10 codes (International Statistical Classification of Diseases and Related Health Problems, 10th Revision). Several groups have reported ICD-9 coding errors in inpatient data that have implications for research, quality improvement, and policymaking, but few have assessed ICD-10 code validity in ambulatory care databases. Our objective was to evaluate pulmonary embolism (PE) ICD-10 code accuracy in our large, integrated hospital system, and the validity of using these codes for operational and health services research using ED ambulatory care databases. METHODS Ambulatory care data for patients (age ≥ 18 years) with a PE ICD-10 code (I26.0 and I26.9) were obtained from the records of four urban EDs between July 2013 to January 2015. PE diagnoses were confirmed by reviewing medical records and imaging reports. In cases where chart diagnosis and ICD-10 code were discrepant, chart review was considered correct. Physicians' written discharge diagnoses were also searched using 'pulmonary embolism' and 'PE', and patients who were diagnosed with PE but not coded as PE were identified. Coding discrepancies were quantified and described. RESULTS One thousand, four hundred and fifty-three ED patients had a PE ICD-10 code. Of these, 257 (17.7%) were false positive, with an incorrectly assigned PE code. Among the 257 false positives, 193 cases had ambiguous ED diagnoses such as 'rule out PE' or 'query PE', while 64 cases should have had non-PE codes. An additional 117 patients (8.90%) with a PE discharge diagnosis were incorrectly assigned a non-PE ICD-10 code (false negative group). The sensitivity of PE ICD-10 codes in this dataset was 91.1% (95%CI, 89.4-92.6) with a specificity of 99.9% (95%CI, 99.9-99.9). The positive and negative predictive values were 82.3% (95%CI, 80.3-84.2) and 99.9% (95%CI, 99.9-99.9), respectively. CONCLUSIONS Ambulatory care data, like inpatient data, are subject to coding errors. This confirms the importance of ICD-10 code validation prior to use. The largest proportion of coding errors arises from ambiguous physician documentation; therefore, physicians and data custodians must ensure that quality improvement processes are in place to promote ICD-10 coding accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)

Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...

متن کامل

Chart validation of inpatient International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) administrative diagnosis codes for venous thromboembolism (VTE) among intravenous immune globulin (IGIV) users in the Sentinel Distributed Database

The Sentinel Distributed Database (SDD) is a database of patient administrative healthcare records, derived from insurance claims and electronic health records, sponsored by the US Food and Drug Administration for evaluation of medical product outcomes. There is limited information on the validity of diagnosis codes for acute venous thromboembolism (VTE) in the SDD and administrative healthcare...

متن کامل

Incidental Findings in Patients Evaluated for Pulmonary Embolism Using Computed Tomography Angiography

Introduction: Pulmonary embolism (PE) is a common lethal disease that its clinical symptoms may be seen in many other diseases. Computed tomography pulmonary angiography (CTPA) is a valuable diagnostic modality for detection of PE. In addition, it can accurately detect the other diseases with clinical symptoms similar to PE. The aim of this study is to evaluate the frequency of PE and nonemboli...

متن کامل

Evaluating adverse drug event reporting in administrative data from emergency departments: a validation study

BACKGROUND Adverse drug events are a frequent cause of emergency department presentations. Administrative data could be used to identify patients presenting with adverse drug events for post-market surveillance, and to conduct research in patient safety and in drug safety and effectiveness. However, such data sources have not been evaluated for their completeness with regard to adverse drug eve...

متن کامل

Improved coding of postoperative deep vein thrombosis and pulmonary embolism in administrative data (AHRQ Patient Safety Indicator 12) after introduction of new ICD-9-CM diagnosis codes.

BACKGROUND Symptomatic venous thromboembolism is a common postoperative complication. The Agency for Healthcare Research and Quality (AHRQ) has developed a Patient Safety Indicator 12 to assist hospitals, payers, and other stakeholders to identify patients who experienced this complication. OBJECTIVES To determine whether newly created and recently redefined ICD-9-CM codes improved the criter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017