Reintroduction of Riva-Rocci measurements to determine systolic blood pressure?

نویسندگان

  • E Verrij
  • G van Montfrans
  • W J Bos
چکیده

INTRODUCTION In 1896, Riva-Rocci introduced the upper arm cuff to measure systolic blood pressure. In 1905, Nicolai Sergeivich Korotkoff added the auscultatory technique, allowing measurement of both systolic and diastolic blood pressure. Both methods have, to our knowledge, never been formally tested against each other. In this study, we want to fill this gap in history. METHODS We measured systolic blood pressure by the Korotkoff sound technique and approximated the Riva-Rocci technique by measuring cuff pressure at the moment that the first pulsation became visible in Finapres readings, at the finger. This proxy of the Riva-Rocci technique allows an objective, offline, analysis. Measurements were performed simultaneously on the same arm in 57 subjects. RESULTS Systolic blood pressure measured by the Korotkoff sound technique was 167+/-30 mmHg (mean +/-SD ). Systolic blood pressure according to the Riva-Rocci technique was 165+/-32 mmHg. The Riva-Rocci technique underestimated measurements with the Korotkoff technique by 1.8+/-4.4 mmHg (NS, p=0.79). CONCLUSION Riva-Rocci measurements of systolic blood pressure may be as good as the traditionally used Korotkoff measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of short-term blood pressure variability on blood pressure determinations.

To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial pressure at Korotkoff phase 1 was 2.1 (95% confidence interval 1.2-3.0) mm Hg higher than the avera...

متن کامل

Pseudohypertension and the measurement of blood pressure.

Riva-Rocci Korotkoff (RRK) blood pressure measurements may overestimate the intra-arterial pressure (IAP) in individual patients. To study pseudohypertension, defined as an overestimation larger than 10 mm Hg, we compared RRK and IAP measurements in 76 patients. These patients were considered to be at risk for pseudohypertension because of high age, hypertension, or vascular disease. RRK measur...

متن کامل

Contact lens dynamometry: the influence of age.

PURPOSE To examine the influence of age on systolic (systOAP) and diastolic (diastOAP) blood pressure in the ophthalmic artery (OA) measured by a new contact lens dynamometer (CLD). METHODS In a prospective cross-sectional clinical trial, 106 eyes of 106 patients (58 women, 48 men) were examined. A nearly uniform age distribution was achieved by recruiting subjects in seven age groups, with a...

متن کامل

Noninvasive method for determining blood pre- ssure and contours of arterial and volume pulses

A noninvasive method for monitoring blood pressure, based on the principles established by Riva-Rocci and Korotkoff (K), is described; it furnishes, after a single compression-deflation cycle of the arm-encircling cuff, values of systolic and diastolic blood pressures as well as the contours of the brachial arterial pulse and the corresponding volume pulse. K-sounds are detected by a single mic...

متن کامل

Reverting to simplicity: palpating SBP.

Blood pressure (BP) measurement in clinical practice was made possible by the pioneering work of a number of clinical scientists and physiologists at the close of the nineteenth century. The work of von Basch, Potain, Hill, Barnard and perhaps most notably Marey, paved the way for the Italian clinician, Scipione Riva-Rocci to introduce the limb-occluding technique for palpatory measurement of S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Netherlands journal of medicine

دوره 66 11  شماره 

صفحات  -

تاریخ انتشار 2008