Effect of low-intensity pulsed ultrasound on posterolateral lumbar fusion of rabbit.

نویسندگان

  • Jian Wang
  • Jian-Wei Li
  • Lei Chen
چکیده

OBJECTIVE To observe the effect of low-intensity pulsed ultrasound in the posterolateral lumbar fusion of rabbit. METHODS A total of 48 New Zealand white rabbits were randomly divided into the observation group and control group, including the autogenous iliac observation group, artificial bone observation group, artificial bone control group and autogenous iliac control group according to the different bone grafting. The posterolateral lumbar fusion of rabbits in each group was analyzed and compared. RESULTS After 4 weeks of treatment using the low-intensity pulsed ultrasound, the fusion in the bone grafting area of observation group was good. There was the relatively dense fusion area between the right transverse process and artificial bone. The left transverse process had been completely fused, with the clear bone trabecula through the fusion area. There was no significant fusion sign in the control group. According to the fusion comparison between two groups, the fusion rate of the observation group was 83.3% and it was significantly higher than the one of the control group (37.5%). Results of the comparison were statistically significant (P<0.05). The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the iliac observation group were significantly higher than ones of the iliac control group (P<0.05). The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the artificial bone observation group were significantly higher than ones of the artificial bone control group (P<0.05). The expression of IL-1, IL-6 and IL-17 4 weeks after the treatment of the observation group was significantly lower than the one of the control group, with the statistical significance (P<0.05). It indicated that the treatment of low-intensity pulsed ultrasound could reduce the expression level of inflammatory factors. CONCLUSIONS The low-intensity pulsed ultrasound can significantly increase the bone grafting fusion rate of the rabbit's posterolateral lumbar fusion. The possible mechanism is that it promotes the lumbar posterolateral endochondral ossification and reduces the inflammatory reaction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR

We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...

متن کامل

LOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING

In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...

متن کامل

Curb the Pain of Spondylolisthesis; Comparing Posterolateral Fusion with Posterior Lumbar Interbody Fusion

Background & Aim: The purpose of this study was to evaluate and compare the pain of patients with spondylolisthesis who had undergone either of the surgery techniques: posterolateral fusion (PLF) or posterior lumbar interbody fusion (PLIF). Methods & Materials/Patients: In a prospective observational study, 102 surgical candidates with low grade degenerative and isthmic spondylolisthesis were e...

متن کامل

Comparing the Effect of Alendronate and Vitamin D Administration on Lumbosacral Fusion and Severity of Low Back Pain in Patients After Posterior Lumbar Fusion Surgery: A Randomized Clinical Trial

Background and purpose: Bone fusion is a dynamic process and availability of calcium and balance of vitamin D can be effective in post spinal cord fusion. There are contradictory results on this issue, so, we decided to compare the effect of administration of vitamin D and alendronate on lumbosacral vertebral fusion in patients undergoing posterior spinal fusion surgery. Materials and methods:...

متن کامل

بررسی اثر امواج اولتراسوند منقطع با فرکانس پایین بر تشکیل کال استخوانی تیبیا در خرگوش( ارزیابی رادیولوژیک و بیومکانیک)

Background and Objective: Application of low intensity ultrasound has been used for treatment of many diseases in medicine and has suggested for accelerating wound healing process, modifying scar tissue and relief of pain. The aim of this study was radiological and biomechanical evaluation of low-intensity pulsed ultrasound on callus formation of tibia in rabbit. Materials and Methods: In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Asian Pacific journal of tropical medicine

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2015