Simple Method to Reduce the Effect of Patient Positioning Variation on Three-Dimensional Motion Analysis During Treadmill Gait

نویسندگان

  • Shigeo Tanabe
  • Eiichi Saitoh
  • Kei Ohtsuka
  • Toshio Teranishi
  • Yutaka Tomita
  • Yoshihiro Muraoka
چکیده

Recently, three-dimensional (3D) closed curve trajectories of markers placed at strategic body locations, called cyclograms or Lissajous-like graphs, are used for treadmill gait analysis. A simple method is presented to reduce the effect of patient positioning variation. After breaking down movement into three components (anterior-posterior, medial-lateral and superior-inferior), the time-series data and time-inverted data are serially concatenated. A fast Fourier transform (FFT) is done, and a high-pass filter (except 0 Hz) is applied to the anterior-posterior and medial-lateral components. Next an inverse FFT is executed, and the posterior half of the outcome, corresponding to time-inverted data, is deleted. The 3D closed curve is then reconstructed. Results showed that the proposed method was able to reduce the effect of patient positioning variation. Since the adjusted curve is simply a symbolized gait pattern, the method might be useful as an adjunct tool in observational gait analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of different walking speed on the gait kinematics of individuals with knee varus

The purpose of current study was to investigate the spatio-temporal gait parameters and knee varus angle during walking at different speeds in young with knee varus. 18 subjects with varus deformity classified at grade 3 of bowleg and 17 healthy subjects, volunteered to participate in this study. The following variables include stance, swing, double support and cycle time, cadence, stride le...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

The effect of increasing running speed on three-dimensional changes of lower limb joint angles in open motor chain and swing phase

Objective Running is known as one of the most popular sports for which there is no time and space limit. Recently, due to lifestyle changes, the use of treadmills for walking and running has increased. However, the biomechanical differences in coordination between running on a treadmill at different speeds have not been sufficiently addressed. The aim of this study was to investigate the effect...

متن کامل

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013