The self-referencing oxygen-selective microelectrode: detection of transmembrane oxygen flux from single cells.

نویسندگان

  • S C Land
  • D M Porterfield
  • R H Sanger
  • P J Smith
چکیده

A self-referencing, polarographic, oxygen-selective microelectrode was developed for measuring oxygen fluxes from single cells. This technique is based on the translational movement of the microelectrode at a known frequency through an oxygen gradient, between known points. The differential current of the electrode was converted into a directional measurement of flux using the Fick equation. Operational characteristics of the technique were determined using artificial gradients. Calculated oxygen flux values matched theoretical values derived from static measurements. A test preparation, an isolated neuron, yielded an oxygen flux of 11.46+/-1.43 pmol cm-2 s-1 (mean +/- s.e.m.), a value in agreement with those available in the literature for single cells. Microinjection of metabolic substrates or a metabolic uncoupler increased oxygen flux, whereas microinjection of KCN decreased oxygen flux. In the filamentous alga Spirogyra greveilina, the probe could easily differentiate a 16.6% difference in oxygen flux with respect to the position of the spiral chloroplast (13.3+/-0.4 pmol cm-2 s-1 at the chloroplast and 11.4+/-0.4 pmol cm-2 s-1 between chloroplasts), despite the fact that these positions averaged only 10.6+/-1.8 microm apart (means +/- s.e.m.). A light response experiment showed real-time changes in measured oxygen flux correlated with changes in lighting. Taken together, these results show that the self-referencing oxygen microelectrode technique can be used to detect local oxygen fluxes with a high level of sensitivity and spatial resolution in real time. The oxygen fluxes detected reliably correlated with the metabolic state of the cell.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-referencing optrode technology for non-invasive real-time measurement of biophysical flux and physiological sensing.

Vibrating probe technology has enabled scientific investigations that have expanded our knowledge of form and function in biology, but the emergence of new fields of cytomics and physiomics will require new technologies to probe the functional realm of living cells. In this paper, we present the development of a self-referencing optrode, which represents the next generation of biophysical flux ...

متن کامل

Measurement of extracellular ion fluxes using the ion-selective self-referencing microelectrode technique.

Cells from animals, plants and single cells are enclosed by a barrier called the cell membrane that separates the cytoplasm from the outside. Cell layers such as epithelia also form a barrier that separates the inside from the outside or different compartments of multicellular organisms. A key feature of these barriers is the differential distribution of ions across cell membranes or cell layer...

متن کامل

A self referencing platinum nanoparticle decorated enzyme-based microbiosensor for real time measurement of physiological glucose transport.

Glucose is the central molecule in many biochemical pathways, and numerous approaches have been developed for fabricating micro biosensors designed to measure glucose concentration in/near cells and/or tissues. An inherent problem for microsensors used in physiological studies is a low signal-to-noise ratio, which is further complicated by concentration drift due to the metabolic activity of ce...

متن کامل

Detection of Ultraweak Photon Emission (UPE) from Cells as a Tool for Pathological Studies

Objective: It is well-known that all living cells emit ultra-weak photon emission (UPE), which is due to byproducts of chemical reactions in cell metabolisms. It has been shown that Reactive Oxygen Species (ROS) in the cells enhances the UPE intensity. The magnitude of such UPE is extremely weak (i.e. a few to 103 photons/ (sec.cm2)), and the detection of such ultra-weak signals is hardly possi...

متن کامل

Determination of Sediment Oxygen Demand in the Ziya River Watershed, China: Based on Laboratory Core Incubation and Microelectrode Measurements

A study coupling sedimentcore incubation and microelectrode measurement was performed to explore the sediment oxygen demand (SOD) at 16 stations in the Ziya River Watershed, a severely polluted and anoxic river system in the north of China. Total oxygen flux values in the range 0.19-1.41 g/(m²·d) with an average of 0.62 g/(m²·d) were obtained by core incubations, and diffusive oxygen flux value...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of experimental biology

دوره 202 Pt 2  شماره 

صفحات  -