Color stability of laboratory glass-fiber-reinforced plastics for esthetic orthodontic wires

نویسندگان

  • Toshihiro Inami
  • Yasuhiro Tanimoto
  • Naomi Minami
  • Masaru Yamaguchi
  • Kazutaka Kasai
چکیده

OBJECTIVE In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fibers were prepared for esthetic orthodontic wires using pultrusion. These laboratory GFRP wires are more transparent than the commercially available nickel-titanium wire; however, an investigation of the color stability of GFRP during orthodontic treatment is needed. Accordingly, in the present study, the color stability of GFRP was assessed using colorimetry. METHODS Preparation of GFRP esthetic round wires (diameter: 0.45 mm [0.018 inch]) using pultrusion was described previously. Here, to investigate how the diameter of fiber reinforcement affects color stability, GFRPs were prepared by incorporating either 13-µm (GFRP-13) or 7-µm glass (GFRP-7) fibers. The color changes of GFRPs after 24 h, and following 1, 2, and 4 weeks of coffee immersion at 37℃, were measured by colorimetry. We evaluated the color stability of GFRPs by two evaluating units: the color difference (ΔE(*)) and National Bureau of Standards (NBS). RESULTS After immersion, both GFRPs showed almost no visible color change. According to the colorimetry measurements, the ΔE(*) values of GFRP-13 and GFRP-7 were 0.73-1.16, and 0.62-1.10, respectively. In accordance with NBS units, both GFRPs showed "slight" color changes. As a result, there were no significant differences in the ΔE(*) values or NBS units for GFRP-13 or GFRP-7. Moreover, for both GFRPs, no significant differences were observed in any of the immersion periods. CONCLUSIONS Our findings suggest that the GFRPs will maintain high color stability during orthodontic treatment, and are an attractive prospect as esthetic orthodontic wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints

THE PURPOSE OF THIS LONGITUDINAL PROSPECTIVE RANDOMIZED STUDY WAS TO EVALUATE THE RELIABILITY OF TWO DIFFERENT TYPES OF ORTHODONTIC RETAINERS IN CLINICAL USE: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients ...

متن کامل

Contemporary Esthetic Orthodontic Archwires – A Review

Growing demand of invisible braces byesthetically conscious patients has led to remarkable inventions in materials for esthetic labial archwires. Archwires with excellent optical clarity and mechanical properties comparable to conventional archwires have been manufactured by almost all the leading companies of orthodontic products in the past two decades, but their clinical use is still limited...

متن کامل

Comparison between fiber-reinforced polymers and stainless steel orthodontic retainers

Objective The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting...

متن کامل

Effects of fibers on the color change and stability of resin composites after accelerated aging.

Composite resins were reinforced with glass and polyethylene fibers in this study, and the effect of fiber reinforcement on the color change of composite resins was investigated. After accelerated aging, the effect of fiber reinforcement on the color stability of composite resins was also examined. There were three experimental groups (n=12 disks per group): non-fiber-reinforced composite (non-...

متن کامل

Color stability and fluorescence of different orthodontic esthetic archwires.

OBJECTIVE To evaluate the color stability of six esthetic archwires at different time periods and their fluorescence. MATERIALS AND METHODS Samples were evaluated after 7, 14, and 21 days of immersion in staining solution. Color measurements were performed by means of a spectrophotometer according to the Commission Internationale de I'Eclairage L*a*b* system, and color changes (ΔE*) and Natio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2015