Real-time volumetric optical coherence tomography OCT imaging with a surgical microscope
نویسندگان
چکیده
Optical coherence tomography is a unique technique to visualize subsurface tissue structures with a resolution below 10μm during microsurgery without tissue contact. Since it was introduced more than 15 years ago imaging speed was boosted by more than three orders of magnitude, from less than 100 to more than 300,000 A-scans per second. Instead of taking only still images of anatomical structures, the increased speed of OCT allows now to image volumes nearly in real time. This enables not only the scanning of larger tissue surfaces, but also opens new application beyond simple diagnosis. A noncontact volumetric imaging with less than 15 μm resolution can guide microsurgery at the eye, in Otolaryngology (ENT) and in other medical disciplines. Here we present an ultrahigh speed OCT system with more than 200.000 A-scans/second integrated into a surgical microscope (MÖLLER Hi-R 1000, MöllerWedel GmbH, Wedel, Germany), which is capable of processing, rendering and displaying more than 7 volumes with 12 million pixel per second by using a PC with a high performance graphics accelerator card. Best performance was reached by distributing the calculation of the A-scans to the four cores of the PC, whereas the preprocessing and rendering was done in real-time with dedicated software on graphic processing unit (GPU). Possible applications of the system are OCT guided microsurgery in the middle ear or tumor surgery of the vocal fold. Published: 29 October 2010
منابع مشابه
Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery
Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception an...
متن کاملIntraoperative spectral domain optical coherence tomography for vitreoretinal surgery.
We demonstrate in vivo human retinal imaging using an intraoperative microscope-mounted optical coherence tomography system (MMOCT). Our optomechanical design adapts an Oculus Binocular Indirect Ophthalmo Microscope (BIOM3), suspended from a Leica ophthalmic surgical microscope, with spectral domain optical coherence tomography (SD-OCT) scanning and relay optics. The MMOCT enables wide-field no...
متن کاملNovel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography
Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previousl...
متن کاملThe use of optical coherence tomography in intraoperative ophthalmic imaging.
Optical coherence tomography (OCT) has transformed diagnostic ophthalmic imaging but until recently has been limited to the clinic setting. The development of spectral-domain OCT (SD-OCT), with its improved speed and resolution, along with the development of a handheld OCT scanner, enabled portable imaging of patients unable to sit in a conventional tabletop scanner. This handheld SD-OCT unit h...
متن کاملIntrasurgical Human Retinal Imaging With Manual Instrument Tracking Using a Microscope-Integrated Spectral-Domain Optical Coherence Tomography Device.
PURPOSE To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. METHODS Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static...