Mechanical and free living comparisons of four generations of the Actigraph activity monitor

نویسندگان

  • Mathias Ried-Larsen
  • Jan Christian Brønd
  • Søren Brage
  • Bjørge Herman Hansen
  • May Grydeland
  • Lars Bo Andersen
  • Niels Christian Møller
چکیده

BACKGROUND More studies include multiple generations of the Actigraph activity monitor. So far no studies have compared the output including the newest generation and investigated the impact on the output of the activity monitor when enabling the low frequency extension (LFE) option. The aims were to study the responses of four generations (AM7164, GT1M, GT3X and GT3X+) of the Actigraph activity monitor in a mechanical setup and a free living environment with and without enabling the LFE option. METHODS The monitors were oscillated in a mechanical setup using two radii in the frequency range 0.25-3.0 Hz. Following the mechanical study a convenience sample (N = 20) wore three monitors (one AM7164 and two GT3X) for 24 hours. RESULTS The AM7164 differed from the newer generations across frequencies (p < 0.05) in the mechanical setup. The AM7164 produced a higher output at the lower and at the highest intensities, whereas the output was lower at the middle intensities in the mid-range compared to the newer generations. The LFE option decreased the differences at the lower frequencies, but increased differences at the higher. In free living, the mean physical activity level (PA) of the GT3X was 18 counts per minute (CPM) (8%) lower compared to the AM7164 (p < 0.001). Time spent in sedentary intensity was 26.6 minutes (95% CI 15.6 to 35.3) higher when assessed by the GT3X compared to the AM7164 (p < 0.001). Time spend in light and vigorous PA were 23.3 minutes (95% CI 31.8 to 14.8) and 11.7 minutes (95% CI 2.8 to 0.7) lower when assessed by the GT3X compared to the AM7164 (p < 0.05). When enabling the LFE the differences in the sedentary and light PA intensity (<333 counts*10 sec-1) were attenuated (p > 0.05 for differences between generations) thus attenuated the difference in mean PA (p > 0.05) when the LFE option was enabled. However, it did not attenuate the difference in time spend in vigorous PA and it introduced a difference in time spend in moderate PA (+ 3.0 min (95% CI 0.4 to 5.6)) between the generations. CONCLUSION We observed significant differences between the AM7164 and the newer Actigraph GT-generations (GT1M, GT3X and GT3X+) in a mechanical setup and in free-living. Enabling the LFE option attenuated the differences in mean PA completely, but induced a bias in the moderate PA intensities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children?

BACKGROUND A recent review concludes that the agreement of data across ActiGraph accelerometer models for children and youth still is uncertain. The aim of this study was to evaluate the agreement of three generations of ActiGraph accelerometers in children in a free-living condition. METHODS Sixteen 9-year-olds wore the ActiGraph AM7164, GT1M and GT3X+ simultaneously for three consecutive da...

متن کامل

Author's response to reviews Title:Comparison of three generations of ActiGraph activity monitors under free-living conditions: Do they provide comparable assessments of overall physical activity in 9-year old children? Authors: May Grydeland ([email protected])

Title:Comparison of three generations of ActiGraph activity monitors under free-living conditions: Do they provide comparable assessments of overall physical activity in 9-year old children?

متن کامل

Comparing the performance of three generations of ActiGraph accelerometers.

ActiGraph accelerometers are a useful tool for objective assessment of physical activity in clinical and epidemiological studies. Several generations of ActiGraph are being used; however, little work has been done to verify that measurements are consistent across generations. This study employed mechanical oscillations to characterize the dynamic response and intermonitor variability of three g...

متن کامل

Validity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometer

BACKGROUND For many patients clinical prescription of walking will be beneficial to health and accelerometers can be used to monitor their walking intensity, frequency and duration over many days. Walking intensity should include establishment of individual specific accelerometer count, walking speed and energy expenditure (VO2) relationships and this can be achieved using a walking protocol on...

متن کامل

Validation of the Actiheart Monitor for the Measurement of Physical Activity

Int J Exerc Sci 2(1) : 60-71, 2009. The Actiheart monitor uniquely allows simultaneous measurement of heart rate and movement counts. The purpose of this study was to establish validity evidence for the Actiheart monitor under laboratory and free-living conditions. A total of 34 college students (17 males and 17 females, age = 21.8 ± 3.6 years) participated in the study. In the laboratory envir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2012