A report on an implantable electronic cardiac pacemaker.

نویسنده

  • A Kantrowitz
چکیده

The cardiac pacemaker, although comparatively new, is no longer in an experimental stage. It is now in the armamentarium of medical men and surgeons concerned with treating complete heart-block with Stokes-Adams seizures. Four or five years ago, when the need for such a device became obvious, several centers started working on different types of pacemakers that were reported almost simultaneously. Senning and Elmqvistl were probably the first to develop a permanently implantable electronic pacemaker (1959). Made by the Elema Company in Sweden, it had a passive receiver and an external power source. Chardack and associates"." in Buffalo, Zoll and co-workers4 in Boston, our group at Maimonides,5.s and other^^-^ developed implantable devices based on essentially the same principle. Weirich and associateslO had previously shown that far less energy is required to stimulate the heart with electrodes implanted in the myocardium than with Zoll's external stimulation method. Our pacemaker, developed with the General Electric Company, has undergone a number of modifications. The first unit was round, about 2.5 cm. in diameter, and weighed 4 oz. Its components were potted in epoxy resin and the case was of Teflon. Placed in an abdominal pocket, its electrodes were passed through a tunnel to the myocardium of the left ventricle where they were securely embedded. This device was extensively tested in dogs with good results, and we eventually used a similar one in our first clinical case, but it gave us some difficulties. The latest model has essentially the same components: 5 batteries, 2 transistors, 3 resistors, and 1 capacitor (Fig. 1). It has been amply demonstrated that the fewer the components in a device, the higher is its potential for safety and reliability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

NASPE training requirements for cardiac implantable electronic devices: selection, implantation, and follow-up.

Cardiac implantable electronic devices (CIEDs) have become frequently used therapeutic modalities. CIEDs include pacemakers, implantable cardioverter defibrillators (ICDs), devices for heart failure management (cardiac resynchronization), and implantable hemodynamic monitors. Selection of the appropriate CIED, its implantation, and follow-up care require expertise to achieve optimal therapeutic...

متن کامل

Combined Subpectoral Implantation of Implantable Cardioverter-Defibrillator and Augmentation Mammoplasty in a Young Female Patient

Subcutaneous implantation of a cardiac implantable electronic device is the standard method. Occasionally, subpectoral cardiac implantable electronic device (CIED) implantation via axillary incisions is performed in young female patients for cosmetic purposes. Because subpectoral CIED implantation and augmentation mammoplasty involve the same layer, it is feasible to perform both procedures sim...

متن کامل

Infective endocarditis and the pacemaker: cardiac implantable electronic device infection.

We are seeing more implantation of cardiac device such as pacemakers and defibrillators and also cardiac implantable electronic device infection. The infection may affect just the pocket site or progress to deeper infection and bacteraemia. Inadequately treated infection may lead to right sided endocarditis, cardiotomy for pacemaker explantation and increased cost and length of stay in the hosp...

متن کامل

Advances in Arrhythmia and Electrophysiology Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections

Advancements in our understanding of cardiac conduction abnormalities and pathophysiology of congestive heart failure coupled with innovations in device manufacturing and programming have helped to create a demand for a plethora of newer cardiovascular devices over the past 3 decades. Appropriate use of cardiovascular implantable electronic devices (CIEDs) in carefully selected patients is asso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Geriatrics

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1967