Identifying and measuring severity of coronary artery stenosis. Quantitative coronary arteriography and positron emission tomography.
نویسنده
چکیده
Q uantifying severity of coronary artery stenosis is becoming increasingly important for many reasons, including evaluation of interventions such as cholesterol control, stress management, pharmacological agents, percutaneous transluminal coronary angioplasty, thrombolysis, and bypass surgery; clinical decisions on medical versus mechanical treatment of coronary artery stenoses; judgment of adequacy of noninvasive diagnostic techniques; understanding the role of fluid dynamics in localizing atheroma at specific sites of an artery exposed to the same risk factors throughout its length; and in silent coronary artery disease, as the only basis for choosing medical or mechanical intervention to prevent sudden death or acute myocardial infarction. There are two fundamental ways of describing stenosis severity based on anatomic and physiological approaches.1 These anatomic and physiological methods are related but provide independent complementary data; each is essential forjudging severity and regression or progression or for making clinical decisions and will be briefly reviewed.
منابع مشابه
Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients.
To assess the accuracy of positron emission tomography (PET) for evaluation of coronary artery disease (CAD), cardiac PET perfusion images were obtained at rest and with dipyridamole-handgrip stress in 193 patients undergoing coronary arteriography. PET images were reviewed by two independent readers blinded to clinical data. Subjective defect severity scores were assigned to each myocardial re...
متن کاملLesions by Dipyridamole Echocardiography Comparison With Positron Emission Tomography and Quantitative Arteriography
Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve,...
متن کاملComparison With Positron Emission Tomography and Quantitative Arteriography
Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve,...
متن کاملQuantitative angiographic measurements of isolated left anterior descending coronary artery stenosis. Correlation with exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile single-photon emission computed tomography.
OBJECTIVES This study sought to assess the value of quantitative coronary arteriography in predicting an ischemic response at exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile (mibi) single-photon emission computed tomography (SPECT) in patients with single-vessel disease of the left anterior descending coronary artery. BACKGROUND The relation between severity of coro...
متن کاملQuantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease.
The clinical utility of exercise thallium-201 single photon emission computed tomography was investigated in 360 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps. Sensitivity for detecting coronary artery disease was comparably high using quantitative and visual analysis, although specificity tende...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 78 2 شماره
صفحات -
تاریخ انتشار 1988